INSTALLATION MANUAL Manual

Chapter 12
Configuring Hardware for the MicroVAX
Information Processors
12-10
If this device: Then:Displays this selftest
error code:
DUALP
1
0000.0005 or 0000.0001 the device is okay.
<> 0000.0005 or
<>0000.0001
replace the module.
SCSIA
2
FFFFFF03 SCSI bus controller is connected to module and device is good.
00000001 disk drive is connected to module and device is good.
01000001 tape drive is connected to the module and device is good.
FFFFFF05 device is offline or not installed at this address. The SCSI ID may be
set incorrectly or the cabling may be disconnected. Check the cabling
and SCSI ID, then retest.
FFFFFFFF device not tested - possible SCSI bus controller error
SCSIB
2
FFFFFF03 SCSI bus controller is connected to module and device is good.
00000001 disk drive is connected to module and device is good.
01000001 tape drive is connected to the module and device is good.
FFFFFF05 device is offline or not installed at this address.
FFFFFFFF device not tested - possible SCSI bus controller error.
SYS 0000.0001 the device is good.
<> 0000.0001 replace the module.
BPI
2
0000.0001 the device is okay.
<>0000.0001 replace the module.
NI 0000.0001 the Ethernet port and cable are good.
>0000.0001 < 0000.7001 replace the module.
>= 0000.7001 install both Tconnector terminators from the service kit and run the
test again. If you see 0000.0001, then replace the cable. If you do not
see 0000.0001, replace the module.
1
MicroV
AX Information Processor (cat. no. 5730CPU1) only
.
2
MicroV
AX Information Processor EP or EE (cat. nos. 5731CPU1, CPU2) only
.
3. Record the Ethernet address. It is on the second line of the system
configuration display table. For example:
ID 00-00-BC-01-01-C7
Run System Exerciser
You can use the system exerciser to:
test interaction between MicroVAX Information Processor devices
help determine the cause of intermittent problems
give more information about errors associated with the SCSI PORT
or LOADER