INSTALLATION MANUAL Manual
Chapter 12
Configuring Hardware for the MicroVAX
Information Processors
12-4
See Power-up Self-test
To see the power-up self-test display, power up the system.
1. Make sure the terminal is set up and connected to port 3 on the
distribution panel.
2. Power up the MicroVAX Information Processor and the terminal. If
they are already on, reboot them by turning the module’s keyswitch to
Boot. You should see a similar display like this one:
KA42-IN V1.0
F_..E...D...C...B...A...9...8...7...6...5...4_..3_..2...1...
There should be a _ after the F, 4, and 3.
If you see: It means:
...
device tested successfully or has a soft error.
?..
device has a hard error. To find out more information, use
TEST 50 to see the system configuration display.
_..
device not installed or not tested.
*..
device installed but its ROM is destroyed.