To test the industrial disk (5710-ID4, -ID5, -ID6, -ID7), follow the
steps below:
1. Apply power to the industrial disk.
2. Check the indicators.
The indicator labeled: Should be:
If it is not:
CABLE PRESENT ON (If connected to the MicroVAX
Information Processor module)
make sure the cable is secure at the industrial disk
and the MicroVAX Information Processor.
DRIVE #1 DATA ACCESS OFF the MicroVAX Information Processor is accessing
the disk. This is normal.
DRIVE #2 DATA ACCESS
2
OFF the MicroVAX Information Processor is accessing
the disk. This is normal.
DISK POWER ON make sure the power connection is correct
and secure.
PROCESSOR FAULT OFF cycle power. If it does not go OFF, the processor
that controls the disk drive's environment has
faulted. Call support services.
HEATER ON
1
OFF wait a few minutes. It should go OFF (if performing
a cold start, this LED may stay ON for a half hour).
COOLER ON
1
OFF wait a few minutes. It should go OFF (if performing
a hot start, this LED may stay ON for up to an hour
and a half).
1
Either
the HEA
TER ON or COOLER ON LED could be on at startup (depending on the internal temperature of the disk). If both LEDs are ON, call support services.
2
The DRIVE #2 DA
T
A ACCESS indicator is only present on 5710ID5; it is not present on 5710ID4. DRIVE #1 data access and DRIVE #2 data access are not
present at all for 5710ID6 and ID7.
Check
Peripherals