Owner's manual
MultiSightâ„¢ User Manual
Start-up
40 10000000877(02)
Configurable Delays
There are three timing mechanisms that can be used: Trigger Delay, Output Delay, and Output Duration. Each has a range of
0…3000 ms. The following timing diagrams show the behavior of the outputs for each timing mechanism condition.
Case 1: No delay timers used (default state)
Case 2) Trigger Delay = Time (in ms) between the Trigger Input turning on (rising edge) and the image exposure
IN1
(Trigger)
Evaluation Time of Sensor
Ready On
"
Ouput Valid
OUT4
(Ready/Busy)
OUT 1+2
(Pass/Fail)
IN1
(Trigger)
Evaluation
Time
Trigger
Delay
Ready On
"
Ouput Valid
OUT4
(Ready/Busy)
OUT 1+2