Safety Laser Scanner User Manual Instruction Manual

Rockwell Automation Publication 10000337275 Ver 01—October 2014 55
Chapter 12 Technical specifications
Chapter 12
Technical specifications
Fig. 48: Diagram scanning range
2 meter SafeZone Mini
Fig. 49: Diagram scanning range
3 meter SafeZone Mini
OSSD response times
The total response time of your application is dependent on …
The basic response time of the SafeZone Mini.
The multiple sampling set.
The OSSDs used.
The control inputs used.
500
50.1 0.2 0.5 1 2 502010
1
2
5
10
20
50
100
200
Reflectors > 2000%
Reflective films > 300%
White plaster
Writing paper
Grey cardboard
Matte black paint
Black shoe leather
Remission (%)
Protective field
Warning field
Scanning range [m]
500
50.1 0.2 0.5 1 2 502010
1
2
5
10
20
50
100
200
Reflectors > 2000%
Reflective films > 300%
White plaster
Writing paper
Grey cardboard
Matte black paint
Black shoe leather
Remission (%)
Protective field
Warning field
Scanning range [m]