106 Enpac Ex Parameters
Date/Time Sets the data and time in the Enpac Ex. See Setting
the Date, Time, and Date Format on page 22 for
instructions.
Touchscreen Controls the Windows CE touchscreen calibration
routine.
select cmd - Exit this field without selecting an
option.
Calibrate - Immediately starts the Windows CE
touchscreen calibration routine. Once the
calibration routine is finished, the Touchscreen
option will be set to "select cmd."
Options: select cmd (default)
Calibrate
Memory Configures the memory.
select cmd - Exit this field without selecting an
option.
Delete all routes - Deletes all routes and data
from memory.
Initialize - Formats the memory. Deletes all files
from memory including any route files and
directories.
Options: select cmd (default)
Delete all routes
Initialize
Purge Cache Mechanism to speed up the purging point data of
large database. Creates cached empty database file
for faster purging.
Options: On (default)
Off
Note: To maximize storage space, set
Purge Cache to "Off."
Envelope The type of envelope to use for high frequency and
rolling element bearing analysis.
Options: gSE (default)
ESP
Important: Determines which
pre-defined measurement you can use
to collect off route data.
Set Envelope to "ESP" to collect an
off route ESP point. Set Envelope to
"gSE" to collect an off route gSE point.
See Collecting Off Route Data using a
Pre-Defined Measurement on
page 90.