Safety Relay User Manual

MSR241 DeviceNet for Safety System MSR200
12
______________________________________________________________
Troubleshoot with Indicators
The MSR241 has the following indicators:
Module status indicator
Network status indicator
Output status indicators K1 and K2
Module Status Indicator
Indication Status
Off Device not powered
Green Device operational
Flashing green Device needs commissioning due to missing or incorrect
configuration, MSR241 not connected to the Safety
system MSR210
Red Unrecoverable fault
Flashing red Minor fault recoverable, baud rate switches are invalid, MAC
ID or Baud Rate switches are changed while on line or since
reset / power-up
Network Status Indicator
Indication Status
Off Device not powered / Not online
Green Link OK, On line, Connected
Flashing green On line, Not connected
Red Critical link failure
Flashing red Connection timeout
Output Status Indicator K1
Indication Status
Off K1 de-energized
Green K1 energized
Output Status Indicator K2
Indication Status
Off K2 de-energized
Green K2 energized