Installation Instructions Owner's manual
List of recommended relays
MSR126, MSR127, MSR123, MSR124, MSR131, MSR138, MSR211, MSR121, MSR320,
Guardmaster safety relay family (440R-D22R2, 440R-D22S2, 440R-S12R2, 440R-S13R2,
440REM4R2, 440R-EM4R2D), SmartGuard, 1791 DS DeviceNetâ„¢ Safety I/O.
Maintenance
Monthly
Check the correct operation of the switching circuit. Also check for signs of abuse or tampering.
Inspect the switch casing for damage
Repair
If there is any malfunction or damage, no attempts at repair should be made. The unit should be
replaced before machine operation is allowed.
Declaration of Conformity
Rockwell Automation hereby declares that SensaGuard is in conformity with
Directive 2004/108/EC, 2006/42/EC as specified in the Declaration of Conformity
available from www.rockwellautomation.com/products/certification.
PN-75056-179 ver 04 April 2012
12 SensaGuard
TM
Installation Instructions
Check the machine is
isolated and stopped
whenever the interlocked
guard door is open.
IMPORTANT: After
installation and
commissioning, the
actuator, switch and switch
lid fixing screws should be
coated with tamper evident
varnish or similar compound.
R