Owner manual

10.2
Multiple Switches, Automatic Reset, Monitored Output MSR127TP
72697 Issue 4 EO: 28485
10 Magnetically Coded Non Contact Switch Installation Instructions
+24v
0v
Safety A+
Safety A-
Safety B+
Safety B-
Aux
Not
S52 13A1 S11 S12 23
S34 14A2 S21 S22 24
+24V
0V
+24v
0v
Aux
+24v
0v
Aux
White (1)
Green (3)
Yellow (4)
Pink (6)
Grey (5)
Red (8)
Brown (2)
Blue (7)
MC2 MC2
Fuses
L1 L2 L3
K1
K2
MSR127TP
Safety A+
Safety A-
Safety B+
Safety B-
Safety A+
Safety A-
Safety B+
Safety B-
Red
Grey
Pink
Yellow
+24v
0v
Aux
Safety A+
Safety A-
Safety B+
Safety B-
+24v
0v
Aux
Safety A+
Safety A-
Safety B+
Safety B-
Actuator in place LED Green Actuator in place LED Green
Actuator NOT in place LED Red
Actuator in place Flashing LED Green Actuator in place Flashing LED Green
MC2 MC2 MC2
Green (3)
Green (3)
Green (3)
Green (3)
White (1)
White (1)
White (1)
White (1)
Pink (6)
Pink (6)
Pink (6)
Pink (6)
Yellow (4)
Yellow (4)
Yellow (4)
Yellow (4)
Grey (5)
Grey (5)
Grey (5)
Grey (5)
Red (8)
Red (8)
Red (8)
Red (8)
Blue (7)
Blue (7)
Blue (7)
Blue (7)
Brown (2)
Brown (2)
Brown (2)
Brown (2)
24 24
24 24
S1 S2
S3
S4
S5
Note: To maintain diagnostic function
the Red (QD pin 8) wire from the
first switch (S1 in this example)
must be connected to S11
Connected
Not
Connected
Not
Connected
Not
Connected
Not
Connected
Grey Red
Pink
Yellow
Grey
Red
Pink
Yellow
Grey
Red
Pink
Yellow
Grey
Red
Pink
Yellow