Safety Interface M8200 Relay Module Owner's manual

75
75035-119-01(A) / K832 / 26-09-00 © Rockwell Automation Milwaukee, Wisconsin All rights reserved
Operating instructions
M 8200
GB
2.1 Areas of use of the device
The M 8200 can be used to provide voltage free contacts from
most safety devices. Functions such as restart interlock and
contactor monitoring are carried out by the M 8200 in a
simple manner.
Both electronic (semi-conductor) and electromagnetic (relay)
sensor signals can be processed as input signals. In case of
relay outputs, the following must be considered: to prevent
short circuits between the output signals, the wires must be
individual shielded and the shields must be linked to 0 V.
Control cabinet operation
The M 8200 is suitable only for installation in control cabinets.
2 Safety
Safety
Chapter 2
Warning