Rockwell Automation Publication 440G-UM004C-EN-P - August 2020 45
Chapter 7 Application Examples
Wire to ArmorBlock
Guard I/O Module
The 440G-MZ safety switch can be connected to a 1732ES/1732DS ArmorBlock
Guard I/O™ module by using a catalog number 889D-F5NCDM-x 5-wire
patchcord. An example schematic is shown in Figure 26
.
Figure 26 - ArmorBlock Schematic
Figure 27 shows the General tab of the ArmorBlock module properties. The
Input Status must be set to Combined Status - Muting and the Output Data
must be set to Combined.
Figure 27 - Module Properties - General
1732ES-IB12XOB4
K1
K2
889D-E5NC-10
100S Contactors or
700S or 700-HPS Relays
K2
889D-E5NC-10
White (2) A1 A2 Blue (3)
Black(4) A1 A2 Gray (5)
K1
889D-F5NCDM-X
Brown (1) White (2)
Black (4) Gray (5)