Chapter 7 Application Examples
Wire to POINT Guard I/O
Module
Figure 18 shows a wiring example of a 440G-MZ Power to Release safety switch
that is connected to a 1734 POINT Guard I/O™ module.
Figure 18 - 1734 Module and 440G-MZ Safety Switch Schematic
Figure 19 shows the General tab of the 1734-AENTR module properties.
The Input Status can be set to Rack Optimization, Enhanced Rack
Optimization, or Combined Status - Power - Muting as these settings are used
by the Dual Channel Input Stop (DCS) logic block to verify that the 1734-IB8S
switch is operational. The Output Data must be set to Test, as the test outputs
are used to generate test pulses for the output contactors, K1 and K2.
Figure 19 - 1734-AENTR Module Properties - General
1734-IB8S S8BO-4371TNEA-4371
24V DC Com
I0
I1
I2
T0
I3
T1M
COM COM
I5
I6
T2
I7
T3M
COM COM
0
1
2
6
3
7
O0
O1
O2 O3
COM COM
O4
O5
O6 O7
COM COM
COM COM COM COM
+24V DC
K1
K2
Ethernet I/P
to GuardLogix®
PLC and HMI
K2
K1
Blue (Gnd)
Brown (+24)
440G-MZS20*NR*
Power to Release
No aux
Gray - Lock Cmd
White - OSSD 1
Black - OSSD 2
889D-F5NC-X
Safety Gate
440G-MZ