34 Rockwell Automation Publication 440G-UM004C-EN-P - August 2020
Chapter 7 Application Examples
Stopping
Normal production stops are performed by pressing Stop. Access through the 
safety gate is initiated by pressing the Gate Unlock Request. The Y32 output of 
the GLT safety relay turns OFF, which commands the PowerFlex® drive to 
bring the motor to a stop. After the configured time delay (8 seconds) expires, 
the GLT safety outputs turn off, and the gate becomes unlocked. After you 
leave the cell and close the gate, press Reset to lock the gate and return the 
machine to a production state.
The circuit meets the safety requirements up to Category 3, Performance 
Leveld in accordance with ISO 13849-1 and SIL CL 2 in accordance with IEC 
62061.