Installation Instructions User Manual
OPERATING MARGIN
1. The operating margin is parenthesis are for diffuse white surfaces
that fill the control’s field of view.
2. 6.1% and 2.6% designate dark colored surfaces having diffuse re-
flectance of 6.1% and 2.6% respectively compared to diffuse white.
3. The 2.6% surface is Krylon # 1602 Ultra flat black.
TYPICAL RESPONSE CURVE
OPERATING MARGIN
OPERATING DISTANCE
100X
10X
.1”
(.254cm)
1000x
1X
.3”
(.762cm)
.5”
(1.27cm)
.8”
(2.032cm)
2”
(5.08cm)
4”
(10.16cm)
6”
(15.24cm)
8”
(20.3cm)
10”
(25cm)
12”
(30cm)
SUPPRESSION SET FOR 8 (20.3CM)
TYPICAL SUPPRESSION CURVE
DISTANCE TO SENSED OBJECT
DISTANCE TO BACKGROUND OBJECT
14
(35.5cm)
12
(30.5cm)
10
(25.4cm)
8
(20.3cm)
6
(15.2cm)
4
(10.1cm)
2
(5.08cm)
0
0 2
(5.08cm)
4
(10.1cm)
6
(15.2cm)
8
(20.3cm)
10
(25.4cm)
12
(30.5cm)
14
(35.5cm)
(OPERATING MARGIN) M- 16
(OPERATING MARGIN) M-38
WHITE PAPER
6.1%
2.6%
WIRING
All external wiring should conform to the NationalElectric Code and
applicable local codes. See wiring diagrams for external connections.
L1
Black
L1
NC
C
Yellow (Common)
Orange
NO
Blue
Load
L2
White
L2
E--M RELAY
OUTPUT
TERMINAL BASE
42MTB-5000 120VAC
42MTB-5001 240VAC
42MTB-5002 48VAC/DC
42MTB-5003 24VAC
TYPICAL WIRING DIAGRAMS
L1
Black
L1
NC
C
Yellow (Common)
Orange
NO
Blue
Load
L2
White
L2
SOLID STATE
RELAY OUTPUT
TERMINAL BASE
42MTB-5000 120VAC
42MTB-5001 240VAC
42MTB-5002 48VAC/DC
42MTB-5003 24VAC
+
(+)
3
2
1
TTL Logic
--
Black
(--)
TERMINAL BASE
Programmable
Controller
DC Interface
10--30VDC
+5VDC
42MTB-5004
with 8-593
Blue
Grey
Orange
Red