User Manual
Installation Instructions
MiniSightt Photoelectric Sensors
AC/DC Sensors
Retroreflective Diffuse
Wide Angle
Diffuse
Polarized
Retroreflective
Large Aperture
Fiber Optic
Small Aperture
Fiber Optic
Visible Red Fixed Focus
Transmitted Beam
Receiver Source
1 Catalog Number 4 2 K L -- U 2 T C -- X X 42KL--D1TC--XX 4 2 K L -- W 1 T C -- X X 42KL--P2TC--XX 42KL--G1TC--XX 42KL--L2TC--XX 42KL--F2TCS--XX 42KL--F2TCL--XX
42KL--RTCV--XX
42KL--RTC--XX 42KL--E1QZB--XX
2 Sensing Distance 5m (16.4ft) 380mm (15in) 180mm (7in) 2m (6.6ft) Depends on Fiber Depends on Fiber 16mm (0.63in) 43mm (1.7in) 4m (13ft) 30m (98ft)
3 Outputs Two Wire Light/Dark Selectable —
4 Supply Voltage 21.6--250V AC/DC
5 Load Current 100mA max —
6 Leakage Current 1.7mA rms max —
7 Power Consumption 4VA max
8 Response Time 8.3ms 16.6ms max
9 Approvals UL recognized, CSA, CE marked for all applicable directives
10 Protections Short Circuit, Reverse Polarity, False Pulse
11 Indicators Green = Power Yellow = Output Orange = 2.5X Margin, Flashing for Short Circuit Protection
12 Field of View
1.5_ 5_ 18_ 1.5_
Depends on Fiber Depends on Fiber — —
7_
13 Transmitting LED Visible Red 660nm Infrared 880nm Visible Red 660nm Infrared 880nm Visible Red 660nm — Infrared 880nm
14 Sensitivity Adjustment Yes: 11 turn, clutch protected —
15 Operating T emperature -- 4Fto+158F(--20Cto+70C)
16 Housing—Cover—Lens Material Noryl N190—Radel R5000—Acrylic
17 Operating Environment NEMA 4X, 6P, IP67, withstands 8270kPa (1200 psi) washdown
Catalog Number Key—XX could equal
A2 = 2m, 300V cable F4 = pigtail w/4-pin DC micro QD G3 = pigtail w/3-pin AC micro QD Y4 = pigtail w/4-pin DC pico QD X4 =custom 4-pin connector
Not all variations available. Contact factory for availability.
DC Sensors
Retroreflective Diffuse
Wide Angle
Diffuse
Polarized
Retroreflective
Large Aperture
Fiber Optic
Small Aperture
Fiber Optic
Visible Red Fixed Focus
Visible Green
Fixed Focus
Transmitted Beam
Receiver Source
1 Catalog Number 42KL--U2LB--XX 42KL--D1LB--XX 42KL--W1LB-- XX 42KL--P2LB --XX 42KL--G1LB--XX 42KL--L2LB--XX 42KL--F2LBS--XX 42KL--F2LBL--XX 42KL--F3LBS--XX
42KL--RLBV --XX
42KL--RLB--XX 42KL--E1EZB--XX
2 Sensing Distance 5m (16.4ft) 380mm (15in) 180mm (7in) 2m (6.6ft) Depends on Fiber Depends on Fiber 16mm (0.63in) 43mm (1.7in) 16mm (0.63in) 4m (13ft) 30m (98ft)
3 Outputs NPN/PNP Light/Dark Selectable —
4 Supply Voltage 10.8--30V DC
5 Load Current 100mA max —
6 Leakage Current 0.1mA max —
7 Power Consumption 1.5W max
8 Response Time 1ms max 15ms max
9 Approvals UL, CSA, CE marked for all applicable directives
10 Protections Short Circuit, Reverse Polarity, False Pulse
11 Indicators Green = Power Yellow = Output Orange = 2.5X Margin, Flashing for Short Circuit Protection Green = Power
12 Field of View
1.5_ 5_ 18_ 1.5_
Depends on Fiber Depends on Fiber — — —
7_
13 Transmitting LED Visible Red 660nm Infrared 880nm Visible Red 660nm Infrared 880nm Vi sible Red 660nm Visible Green
525nm
— Infrared 880nm
14 Sensitivity Adjustment Yes: 5 turn, clutch protected —
15 Operating Temperature -- 4Fto+158F(--20Cto+70C)
16 Housing—Cover—Lens Material Noryl N190—Radel R5000—Acrylic
17 Operating Environment NEMA 4X, 6P, IP67, withstands 8270kPa (1200 psi) washdown
Catalog Number Key—XX could equal
A2 = 2m, 300V cable F4 = pigtail w/4-pin DC micro QD G3 = pigtail w/3-pin AC micro QD Y4 = pigtail w/4-pin DC pico QD X4 =custom 4-pin connector
Not all variations available. Contact factory for availability.
When using the transmitted beam sensing mode in high noise (EMF) applications, it is recommended that the 42KL--RxxV receiver be used whenever possible. This will prevent the sensor from “locking on” due to high line voltage
spikes.