Manual

1
Installation Instructions
RightSightt DeviceNett PHOTOSWITCH
R
Photoelectric Sensors
Sensing Mode
Polarized
Retroreflective
Diffuse
Sharp
Cutoff Diffuse
Background Suppression
Glass
Fiber Optic
Transmitted Beam
Version 50mm (2in) 100mm (4in) 20m Receiver 4m Receiver Source
Cat No.
5-pin micro QD 42EF- P2LDB- F5 42EF- D1LDAK- F5 42EF- SIMDA- F5 42EF- B1LDBC- F5 42EF- B1LDBE - F5 42EF- G1LDA- F5 42EF- R9LDB- F5 42EF - R9LDBV- F5 42EF- E1EDZB- F5
2m cable Consult f actory 42EF- E1EZB- A2
Optical
1 Sensing Distance 3m (9.8ft) 500mm (20in) <127mm (5in) 50mm (2in) 100mm (4in)
Varies with fiber op-
tic cable
20m (60ft) 4m (13ft) 20m (60ft)
2 Field of View
1.5_ 5_ 7_ 20_ 8_ 7_
Not applicable
3 Transmitting LED Visible Red 660nm Infrared 880nm Not applicable Infrared 880nm
4 Sensitivity Adjustment No Yes No Yes No
Electrical
5 Supply Voltage 11--25V DC
6 Current Consumption 65mA maximim
7 Power Consumption 1.6W maximum
8 Response Time 3ms 3ms 3ms 3ms 3ms 3ms 11ms 11ms Not applicable
9 Protection Output: short circuit protected, Power: Reverse polarity, False Pulse (300ms power ON delay)
Power: Reverse
polarity
Mechanical
10 Housing Material Mindel
11 Lens Material Acrylic
12 Indicators SeeTable1. Green: Power
Environmental
13 Operating Temperature
-- 2 5 _ to +70_C(--13_ to +158_F)
14 Operating Environment NEMA 4X, 6P, IP67; 8270kPa (1200psi) washdown
15 Vibration 10--55Hz, 1mm amplitude, meets or exceeds IEC 947--5--2
16 Shock 30G, meets or exceeds IEC 947--5--2
17 Relative Humidity 95%
18 Approvals UL, CSA, CE for all applicable directives, DeviceNet conformance tested
DeviceNet
19 Network Interface DeviceNet
20 Protocol Selectable Change-of-State (COS) or Strobing
21 Operating Mode Selectable Light/Dark operate
22 Autobaud Detect Selectable ON/OFF
23 Communication Rate Selectable 125kb, 250kb, 500kb
24 Supported Node Address Selectable 0 to 63 (63 factory default)
25 Timer ON Delay and OFF Delay/One Shot (0 to 65,535ms, 1 or 10ms time base)
26 Counter Adjustable with output bit (0 to 65,535 counts)
27 Motion Detect Adjustable with output bit (0 to 65,535ms, 1ms time base)
28 Margin Diagnostic Selectable with dual thresholds (0.7 to 1.5 and 0.7 to 2.0)
29 Margin Diagnostic Type Selectable static or dynamic

Summary of content (4 pages)