User Manual Owner's manual
144 Rockwell Automation Publication 290D-UM001A-EN-P - June 2012
Chapter 4 Bulletin 290D/291D/294D Programmable Parameters
DecelTime2
When active, sets the rate of deceleration for all speed decreases except for jog.
Parameter Number 70
Related Parameters 37
Access Rule GET/SET
Data Type UINT
Group Advanced Config.
Units x.x secs
Minimum Value 0.0
Maximum Value 600.0
Default Value 20.0
Maximum Freq
Decel Time
-------------------------------------- D e c e l R a t e=
Parameter 35
(Maximum Freq)
Speed
Accel
Time 2
0
0
Time Decel
Time 2
Acceleration
Deceleration
MotorOLRetention
Enables/disables the Motor overload
Retention function. When Enabled, the
value held in the motor overload counter
is saved at power-down and restored
at power-up. A change to this parameter
setting resets the counter.
0 = Disabled (Default)
1 = Enabled
Parameter Number 71
Access Rule GET/SET
Data Type UINT
Group Advanced Config.
Units —
Minimum Value 0
Maximum Value 1
Default Value 0
InternalFreq
Provide the frequency command to drive
when Parameter 33 (Speed-Reference) =
1 (InternalFreq). When enabled, this
parameter will change the frequency
command in real time.
Parameter Number 72
Related Parameters 33
Access Rule GET/SET
Data Type UINT
Group Advanced Config.
Units x.x Hz
Minimum Value 0.0
Maximum Value 400.0
Default Value 60.0