Safety Version - User Manual User guide

Bulletin 280/281 Programmable Parameters 3-13
Last PR Fault
0 = None
1 = Hardware Short Circuit
2 = Software Short Circuit
3 = Motor Overload
4 = Reserved
5 = Phase Loss
6 – 12 = Reserved
13 = Control Power Loss
14 = Control Power Fuse
15 = I/O Short
16 = Output Fuse
17 = Overtemp
18= Reserved
19 = Phase Imbalance
20 = Reserved
21 = DNet Power Loss
22 = Internal Comm
23-26 = Reserved
27 = MCB EEPROM
28 = Base EEPROM
29 = Reserved
30 = Wrong Base
31 = Wrong CTs
32-100 = Reserved
Parameter Number 61
Access Rule GET
Data Type UINT
Group Starter Protection
Units
MinimumValue 0
Maximum Value 100
Default Value 0
Warning Status
This parameter warns the
user of a condition, without
faulting
Parameter Number 62
Access Rule GET
Data Type WORD
Group Starter Protection
Units
MinimumValue 0
Maximum Value 65535
Default Value 0
Bit
Warning
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
X reserved
X reserved
X Phase Loss
X reserved
X reserved
X Control Power
XIO Warning
X reserved
X Phase Imbalance
X DeviceNet
X reserved
X reserved
X reserved
X H a r d w a r e
X reserved
X reserved