User Manual

Bulletin 280/281 Programmable Parameters 3-25
Zone #1 Key
When the “Security Enable” bit
for zone 1 is enabled, this value
must match the value of the
Device Value Key parameter in
the device whose data is being
consumed for zone 1.
Parameter Number 94
Access Rule GET/SET
Data Type UINT
Group ZIP Parameters
Units
MinimumValue 0
Maximum Value 65535
Default Value 0
Zone #2 Key
When the “Security Enable” bit
for zone 2 is enabled, this value
must match the value of the
Device Value Key parameter in
the device whose data is being
consumed for zone 2.
Parameter Number 95
Access Rule GET/SET
Data Type UINT
Group ZIP Parameters
Units
MinimumValue 0
Maximum Value 65535
Default Value 0
Zone #3 Key
When the “Security Enable” bit
for zone 3 is enabled, this value
must match the value of the
Device Value Key parameter in
the device whose data is being
consumed for zone 3.
Parameter Number 96
Access Rule GET/SET
Data Type UINT
Group ZIP Parameters
Units
MinimumValue 0
Maximum Value 65535
Default Value 0
Zone #4 KEY
When the “Security Enable” bit
for zone 4 is enabled, this value
must match the value of the
Device Value Key parameter in
the device whose data is being
consumed for zone 4
Parameter Number 97
Access Rule GET/SET
Data Type UINT
Group ZIP Parameters
Units
MinimumValue 0
Maximum Value 65535
Default Value 0
Device Value Key
This value is produced in the last
2 bytes of data when one of the
ZIP assemblies is chosen for data
production.
Parameter Number 98
Access Rule GET/SET
Data Type UINT
Group ZIP Parameters
Units
MinimumValue 0
Maximum Value 65535
Default Value 0