User Manual

Bulletin 284 CIP Information D-11
Instance 167 is input (produced) assembly for Inverter Type
Distributed Motor Controllers with Network Outputs
Table D.30 .Instance 167 —Produced Inverter Type Starter with Network
Options
If 284A is selected.
Refers to output contactor status.
Refers to source brake contactor status.
Power Flex Native Assemblies
These assembly instances have the same data format as the Power
Flex Drives with a DNet adapter.
Power Flex Native Consumed Assembly
Instance 170 is the Power Flex Native Format Consumed Assembly
Table D.31 Instance 170 — Power Flex Native Format Consumed Assembly.
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0
At
Reference
Net Ref
Status
Net Ctl
Status
Ready
Running
Rev
Running
Fwd
Alarm Tripped
1
Contactor 2
Contactor 1
140M
On
HOA
Status
User In 4 User In 3 User In 2 User In 1
Reserved
Reserved
Reserved
Reserved
2 Output Frequency (Low) (xxx.x Hz)
3 Output Frequency (High) (xxx.x Hz)
4 Net Out 8 Net Out 7
Net
Out 6
Net
Out 5
Net Out 4 Net Out 3 Net Out 2 Net Out 1
5 Net Out 15
Net
Out 14
Net
Out 13
Net Out
12
Net Out
11
Net Out
10
Net Out 9
6 ZIP Device Value Key (Low)
7 ZIP Device Value Key (High)
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 MOP Inc reserved Direction Cmd Flt Reset Jog Start Stop
1 MOP Dec
Freq Select
3
Freq Select
2
Freq
Select 1
Decel
2
Decel
1
Accel
2
Accel
1
2 Comm Frequency Command (Low)
3 Comm Frequency Command (High)