User Manual
C-8 Bulletin 283 CIP Information
Table C.17 Instance 186 This is a “Read Only” Status Assembly
Table C.18 Instance 187 This is a “Read/Write” Assembly
Table C.19 Instance 189 This is a “Read Only” assembly
➊Reserved for Bulletin 283.
Table C.20 Instance 190 is the 1999-ZCIO Native Format Produced Assembly.
Standard Distributed Motor
Controller I/O Assemblies
Standard Distributed Motor Controller IO Assemblies are available
on all Starter Types.
Instance 186 — DeviceNet Status
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 — — — I/O Idle I/O Flt Exp Flt I/O Cnxn Exp Cnxn
1 ZIP4 FLT
ZIP4
CNXN
ZIP3 FLT
ZIP3
CNXN
ZIP2 FLT
ZIP2
CNXN
ZIP1 FLT
ZIP1
CNXN
Instance 187 — Starter Control Bits
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0
User Out
B
User Out
A
———
Fault
Reset
—Run Fwd
1Reserved
Instance 189 Warning Status Bits
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 — IO Warning
Control
Power
Warning
PR Warning — PL Warning — —
1 — — HW Warn DN Warn
➊ PI Warn
Instance 190 1799-ZCIO Native Format Produced Assembly
Byte Bit 7 Bit 6 Bit 5 Bit 4 Bit 3 Bit 2 Bit 1 Bit 0
0 Running Rev Running Fwd Warning Tripped Input 3 Input 2 Input 1 Input 0
1 Reserved Logic Enable Reserved 140M On HOA
2 Reserved User Out B User Out A Reserved Run Fwd
3 Reserved
4 Net Out 8 Net Out 7 Net Out 6 Net Out 5 Net Out 4 Net Out 3 Net Out 2 Net Out 1
5ZIP CCV (Low)
6 ZIP CCV (High)