User Manual

5-50 Bulletin 284 Programmable Parameters for Volts per Hertz Controllers
Comm Loss Time
Sets the time that the drive remain in communication loss before implanting the
option selected in Parameter 205 (Comm Loss Action).
Parameter Number 206
Related Parameters 115, 205
Access Rule GET/SET
Data Type UINT
Group Advanced Program Group
Units 0.1 sec
Minimum Value 0.1 sec
Maximum Value 60.0 sec
Default Value 15.0 sec
Comm Format
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.
Parameter Number 207
Anlg In 0…10V Lo
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.
Parameter Number 210
Anlg In 0…10V HI
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.
Parameter Number 211
Anlg In4…20MA LO
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.
Parameter Number 212
Anlg In4…20 mA HI
This parameter is not available for use with the ArmorStart Distributed Motor
Controller.
Parameter Number 213
Slip Hertz @ FLA
Compensates for the inherent slip in an induction motor. This frequency is added to
the commanded output frequency based on motor current.
Parameter Number 214
Related Parameter 133
Access Rule GET/SET
Data Type UINT
Group Advanced Program Group
Units 0.1 Hz
Minimum Value 0.0 Hz
Maximum Value 10.0 Hz
Default Value 2.0 Hz
Process Time Lo
Scales the time value when the drive is running at Parameter 134 (Minimum Freq).
When set to a value other than zero, Parameter 110 (Process Display) indicates the
duration of the process.
Parameter Number 215
Related Parameters 110, 134
Access Rule GET/SET
Data Type UNIT
Group Advanced Setup
Units Hz
Minimum Value 0.00
Maximum Value 99.99
Default Value 0.00