User Manual
5-30 Bulletin 284 Programmable Parameters for Volts per Hertz Controllers
Zone #4 KEY
When the “Security Enable” bit for zone 1 is enabled, this value must match the
value of the Device Value Key parameter in the device whose data is being
consumed for zone 4
Parameter Number 97
Access Rule GET/SET
Data Type UINT
Group ZIP Parameters
Units
—
Minimum Value 0
Maximum Value 65535
Default Value 0
Device Value Key
This value is produced in the last 2 bytes of data when one of the ZIP assemblies is
chosen for data production.
Parameter Number 98
Access Rule GET/SET
Data Type UINT
Group ZIP Parameters
Units
—
Minimum Value 0
Maximum Value 65535
Default Value 0
Zone Ctrl Enable
Global enable for ZIP peer-to-peer messaging. This parameter must be disabled
before any changes to the ZIP configuration for the device can be made.
0=Disable
1=Enable
Parameter Number 99
Access Rule GET/SET
Data Type BOOL
Group ZIP Parameters
Units
—
Minimum Value 0
Maximum Value 1
Default Value 0