Owner manual

AB
8
Chapter
81
Specifications
Optical
Nominal Scan Rate 35 scans/second
Wavelength (nominal) 670 nm
Maximum Pitch ±55 degrees
Maximum Skew ±65 degrees
Scanning Range
Minimum
Bar Width
Standard Range
(2755-G3-W)
Long Range
(2755-G6-W)
6.0 mil
(.15 mm)
3.0 in - 5.0 in
7.6 cm - 12.7 cm
N.A.
7.5 mil
(.19 mm)
2.5 in - 7.5 in
6.4 cm - 19.0 cm
N.A.
10.0 mil
(.25 mm)
1.0 in - 10.0 in
2.5 cm - 25.4 cm
N.A.
15.0 mil
(.38 mm)
1.5 in - 14.0 in
3.8 cm - 35.6 cm
8.0 in - 22 in
20.3 cm - 55.9 cm
20.0 mil
(.51 mm)
2.5 in - 18.0 in
6.4 cm - 45.7 cm
12 in - 36 in
30.5 cm - 91.4 cm
40.0 mil
(1.02 mm)
9.0 in - 25.0 in
22.9 cm - 63.5 cm
23 in - 60 in
58.4 cm - 152.4 cm
55.0 mil
(1.40 mm)
12.0 in - 30.0 in
30.5 cm - 76.2 cm
23 in - 66 in
58.4 cm - 167.6 cm
Scanning Range
Autosense Mode 36 in (91.4 cm) maximum
(to reflective label or tape)
Electrical
Supply Voltage 4.75 to 14 VDC
Current Consumption
While Scanning 200 mA maximum
Standby Power 100 mA maximum
Continuous Full Power 200 mA maximum
1
1
Autosense mode automatically uses continuous full power.
Hand Held Scanners
Catalog No. 2755-G3-W
Catalog No. 2755-G6-W