User Manual

Decoder Configuration Addresses A–15
Publication 2755-833
Extended Match Data 8000H–A03FH
The following table lists the configuration parameters for the
Extended Match Data Table. Address the counters by adding the
offset i * 40 H to the base address 8000, where i represents the
counter number, 1 to 128.
PCCC Address Configuration Parameter
Number of
Bytes
Acceptable Values
(Default in bold)
8000H+i*40H Mode 1 0 = Disabled
1 = Match_entry
2 = Auto–Load
3 = Lot
8001H+i*40H Source 1 1 = Scanner A
2 = Scanner B
3 = A|B
5 = A–B
8002H+i*40H symbology 1 0 = Code 39
1 = Interleaved 2–of–5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128
8 = Pharma–Code
F = ANY
8003H+i*40H Reserved 1 1
8004H+i*40H Count 4 0 to 999999
8008H+i*40H Loading: Discrete 1 8 0 = no discrete
1 to 9, or 0aH = always
8009H+i*40H Loading: Discrete 2 8 0 = no discrete
1 to 9, or 0aH = always
800AH+i*40H Loading: Discrete 3 8 0 = no discrete
1 to 9, or 0aH = always
800BH+i*40H Loading: Discrete 4 8 0 = no discrete
1 to 9, or 0aH = always
800CH+i*40H Loading: Discrete 5 8 0 = no discrete
1 to 9, or 0aH = always
800DH+i*40H Loading: Discrete 6 8 0 = no discrete
1 to 9, or 0aH = always
800EH+i*40H Loading: Discrete 7 8 0 = no discrete
1 to 9, or 0aH = always
8008F+i*40H Loading: Discrete 8 8 0 = no discrete
1 to 9, or 0aH = always
8010H+i*40H Reserved 14 1
801EH+i*40H Match pattern – Length
Match pattern – String
1
32
0–32, 0 = Empty
up to 32 characters
803FH+i*40H Reserved 1 1