User Manual
Decoder Configuration Addresses A–13
Publication 2755-833
Acceptable Values
(Default in bold)
Number of
Bytes
Configuration ParameterPCCC Address
E1D Scanner B Start Scan Character 1 ASCII 0 – 255, 255 = None
E1E Scanner B Stop Scan Character 1 ASCII 0 – 255, 255 = None
E1F Extended Match Set 1 (1 – 16) 1 0 = Disabled
1 = Enabled
E20 Extended Match Set 2 (17 – 32) 1 0 = Disabled
1 = Enabled
E21 Extended Match Set 3 (33 – 48) 1 0 = Disabled
1 = Enabled
E22 Extended Match Set 4 (49 – 64) 1 0 = Disabled
1 = Enabled
E23 Extended Match Set 5 (65 – 80) 1 0 = Disabled
1 = Enabled
E24 Extended Match Set 6 (81 – 96) 1 0 = Disabled
1 = Enabled
E25 Extended Match Set 7 (97 – 112) 1 0 = Disabled
1 = Enabled
E26 Extended Match Set 8 (113 – 128) 1 0 = Disabled
1 = Enabled
Host Message Replacement Rules 1000H–143FH
PCCC Address Configuration Parameter
Number of
Bytes
Acceptable Values
(Default in bold)
1000H+i*40H host_message Field 1 0 to 16, 0 = ALL
1001H+i*40H Source 1 1 = Scanner A
2 = Scanner B
3 = A|B
4 = AUX
1002H+i*40H symbology 1 0 = Code 39
1 = Interleaved 2–of–5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128
8 = Pharma–Code
0fh = ANY
1003H+i*40H symbol_number 1 0 to 16, 0 = ALL
1004H+i*40H Minimum Field Length 1 0 to 64
1005H+i*40H Alignment 1 0 = Right
1 = Left
1006H+i*40H Fill Character 1 0 to 255, 0 = None
1007H+i*40H Reserved 1 1
1008H+i*40H Search Pattern Length
Search Pattern
1
24
0–24, 0 = Empty
up to 24 characters
1021H+i*40H Reserved 3 1
1024H+i*40H Replace Pattern Length
Replace Pattern
1
24
0–24, 0 = Empty
up to 24 characters
103DH+i*40H Reserved 3 1