User Manual

Decoder Configuration AddressesA–4
Publication 2755-833
Acceptable Values
(Default in bold)
Number of
Bytes
Configuration ParameterPCCC Address
41A Host Protocol
(read–ONLY)
1 0 = *RS232
1 = RS232 XON/XOFF
2 = RS232 CTS/RTS – 1
3 = RS232 CTS/RTS – 2
4 = RS422
5 = RS422 XON/XOFF
6 = RS485 PCCC – 1
7 = RS485 PCCC – 2
8 = RS485 ASCII – 1
9 = RS485 ASCII – 2
41B Device Address
(read–ONLY)
1 00, 01, ... 31
41C Enable Filter and Sense of Package_Detect_A
Input
1 0 = No Filter, LO=Package
1 = Filter (15 msec), LO=Package
2 = No Filter, HI=Package
3 = Filter (15 msec), HI=Package
41D Enable Code 39 1 0 = No
1 = Yes (No for Pharma–code units)
41E thru 425 Code 39 Specific Lengths 8 0 ... 64
426 Enable Interleaved 2–of 5 1 0 = No
1 = Yes
427 thru 42e Interleaved 2–of 5 Specific Lengths
(Must be even)
8 0 ... 64
42F Enable Code 128 1 0 = No
1 = Yes
430 thru 437 Code 128 Specific Lengths 8 0 ... 64
438 Enable Codabar 1 0 = No
1 = Yes
439 thru 440 Codabar Specific Lengths 8 0, 2... 64
441 Enable UPC–A 1 0 = No
1 = Yes
442 Enable UPC–E 1 0 = No
1 = Yes
443 Enable EAN–8 1 0 = No
1 = Yes
444 Enable EAN–13 1 0 = No
1 = Yes
445 LASER Light (A) 1 0 = On
1 = Triggered
2 = Off
446 Decode Mode 1 0 = Package Detect
1 = Host
2 = Internal Timer
3 = Continuous
4 = Continuous/Unique
447 Capture Count 1 0, 1, 2, ... 8, 0 = Verify
448 symbols/scan 1 0 = Any
1 = 1
2 = 2
3 = 3
4 = 4
5 = 5
6 = 6
449 symbols/package 1 1 ... 16