User Manual
15–63ASCII Host Commands
Publication 2755-833
NM - Configure Default No-Read String
Command Format: NMIIstring
Function: Defines a no-read message for bar codes that
could not be scanned or decoded. No-read
messages are optionally included in messages
sent to the host.
Parameters: ll
string
Command
Parameter
Parameter Function Valid Values
ll Length of no-read message 00 to 32①
String No-read message characters Up to 32 characters
① A zero length string disables a no read string.. A nonzero length string
enables the no read string
Response: = rr <end>
rr = response code
<end> = end of message control code
Example:
Command: NM07NO-READ
Parameters: 07NO-READ
Command
Parameter
Parameter Function Values
ll Length of no-read message 07
String No-read message characters NO-READ
Response: = 00CR
00 = command complete
response code
CR = end of message control code
for Carriage Return