User Manual
15–52 ASCII Host Commands
Publication 2755-833
SF - Set No-Read Replacement Strings
Command Format: SFnnllstring
Function: Set the No-Read Replacement Strings.
Parameters: nnllstring
Command
Parameters
Parameter Function Valid Values
nn
The number of the No-Read
Replacement String
01 to 16
ll
Length of the No-Read
Replacement String
00=Empty or 01 to 24
String No-Read Replacement String up to 24 characters
Response: = rr <end>
rr = response code
<end> = end of message control
code
Example:
Command: SF0207No–Read
Parameters: 02 07 No–Read
Command
Parameters
Parameter Function Values
nn
The number of the No-Read
Replacement String
02
ll
Length of the No-Read
Replacement String
07
String No-Read Replacement String No–Read
Response: = 00CR
00 = command complete
response code
CR = end of message control code
for Carriage Return.