User Manual

15–45ASCII Host Commands
Publication 2755-833
CS - Disable Extended Match Code Set
Command Format: CSnnnnnnnn
Function: Disables a group of Extended Match Codes
Parameters: nnnnnnnn
Command
Parameters
Parameter Function Valid Values
nnnnnnnn
Allows the 128 Extended Match
Codes to be treated as eight
sets of sixteen each. Each set
can be individually marked.
00000000 = All
Disabled
through
11111111=All enabled
Response: = rr <end>
rr = response code
<end> = end of message control code
Example:
Command: CS01100011
Parameters: 01100011
Command
Parameters
Parameter Function Values
nnnnnnnn
Enables positions 17–32, 33–48,
97–112, and 113–128
01100011
Response: = 00CR
00 = command complete
response code
CR = end of message control code
for Carriage Return.