User Manual

15–42 ASCII Host Commands
Publication 2755-833
RP - Read All Extended Match Data (continued)
Example:
Command: RP
Response: 001 M 03 01 001289 04 1289 CR
002 ...
...
128 M 03 01 001289 04 1289 CR
=00CR
Command
Parameters
Parameter Function Values
nnn
The number of the Extended
match counts
064
a Mode M = Match Entry
s Source 03=A|B
cc symbology 01=Code 39
mmmmmm The value of the count 001289
ll Length of match string 04
string Match string 1289
a Mode M = Match Entry
s Source 3=A|B
cc Symbology 01=Code 39
mmmmmm The value of the count 000222
ll Length of match string 04
string Match string 6247
CR = delimiter and/or end of
message control code for
Carriage Return
00 = command complete
response code
CR = end of message control code
for Carriage Return.