User Manual
15–41ASCII Host Commands
Publication 2755-833
RP - Read All Extended Match Data
Command Format: RP
Function: Reads the value of all Extended data.
Parameters: None
Response
Parameters
Parameter Function Valid Values
nnn
The number of the Extended
match counts
001 to 128
a Mode
A=Auto-load
M=Match Entry
D=Disabled
L=Lot
ss Source
01=Scanner A
02=Scanner B
03=A|B
04=A–B
cc Symbology
01=Code 39
02=Interleaved 2-of-5
03=Codabar
04=UPC-A
05=UPC-E
06=EAN-8
07=EAN-13
08=Code 128
09=Pharma–Code
16=Any
mmmmmm The value of the count 000000 to 999999
ll Length of match string 00 to 32
string Match string up to 32 characters
Response: 001assccmmmmmmmmllstring<end>..
...
128assccmmmmmmmmllstring<end>
=rr<end>
rr = response code
<end>= end of message control code