User Manual
15–35ASCII Host Commands
Publication 2755-833
MW - Write Primary Match Code Table Entry (continued)
Example:
Command: MW4102041289
Parameters: 4102041289
Command
Parameters
Parameter Function Values
n Match code table entry number 4
f RESERVED 1
cc Bar code symbology 02=Interleaved 2 of 5
ll Length of match string 04
string Match string 1289
Response: = 00LF
00 = command complete
response code
LF = end of message control code
for Line Feed
CM - Clear Primary Output Counters
Command Format: CMn
Function: Clears the selected output counter to 0.
Parameters: n = output counter number 1 through 8
Response: = rr <end>
rr = response code
<end > = end of message control code
Example:
Command: CM3
Parameters: 3 = output counter #3.
Response: = 00CR
00= command complete
response code
CR = end of message control code
for Carriage Return