User Manual

15–29ASCII Host Commands
Publication 2755-833
OC - Set Output Condition and Output Duration
Command Format: OCnctttt
Function: Sets the condition that will activate an output
and the length of time (in milliseconds) the
output is activated.
Parameters: nctttt
Command
Parameters
Parameter Function Valid Values
n Output number 1 through 8
c Condition activates output
0= None
1= Read (Package)
2= No-Read (Package)
3= Match Complete
4= Match Entry
5= Read and No-Match
6= No-Read or
No–Match
7= Auto Load
8= Auto Load (Input)
9= Host buffer full
A= Host buffer overflow
tttt
Time (in milliseconds) that
output is activated.
0000, 0010 to 9999
(milliseconds)
0000 disables condition
The AutoLoad (Input) function applies only to output 8.
Response: = rr <end>
rr = response code
<end> = end of message control code