User Manual

15–22 ASCII Host Commands
Publication 2755-833
BF - Configure Scanner B Package Detect Filter and Sense
Command Format: BFf
Function: Enables or disables the 15 ms input filter and
determines the sense of the package detect signal
for Scanner B.
NOTE: This command is valid only for dual
head decoders.
Parameters: f = disable or enable filter/select sense.
Command
Parameter
Parameter
Function
Valid Values
f
Enable or disable
filter/select sense
0=disable filter,
LO when package is present
1=enable filter,
LO when package is present
2=disable filter,
HI when package is present
3=enable filter,
HI when package is present
Response: = rr <end>
rr = response code
<end> = end of message control code
Example:
Command: BF1
Parameters: 1
Command
Parameter
Parameter
Function
Value
f
Enable or disable
filter/select sense
1=enable filter,
LO when package is present
Response: = 00CR
00 = command complete
response code
CR = end of message control code
for Carriage Return