User Manual

15–18 ASCII Host Commands
Publication 2755-833
SC - Configure Scanner A Control
Command Format: SCldcsprrrrttttm
Function: Specifies the operating parameters for Scanner
A or Scanners A and B in coordinated mode.
Parameters: ldcsprrrrtttttm
Command
Parameters
Parameter Function Valid Values
l Laser-light
0= On
1= Triggered
2= Off
d Trigger mode
0= Package Detect
1= Host
2= Internal Timer
3= Continuous
4= Continuous/unique
c Capture count.
0, 1 through 8
(0= Verify)
s Bar code symbols per scan
0 through 6
0= ANY (1,2,3,4,5,6)
p
Bar code symbols per
package
1 -9, A-G
(where A=10,...G=16)
rrrr
No-read timer value
(in milliseconds)
0000, 0010 - 9999
(in milliseconds)
0000 disables timeout
tttt
Inter–scan timer value
(in milliseconds)
0000, 0010 - 9999
(in milliseconds)
0000 disables timeout
m Match complete count
1 -9, A-G
(where A=10,...G=16)
Important: See Chapter 6 for a description of
the Scanner Control parameters.
Response: = rr <end>
rr = response code
<end> = end of message control code