User Manual
10–15Configuration: Host Message Replacement Rules
Publication 2755-833
Examples
Example 1: Sorting by Data Source
Parameter Rule #1 Value Rule #2 Value
Source A B
Symbology Any Any
Symbol Number All All
Find String Containing .* .*
Replace Entire String
With
& &
Minimum Field Length 0 0
Alignment Right Right
Fill Character None None
Host Message Field
Number
1 2
In the decode mode Coordinated 1 or 2, two symbols per package
and each scanner reading a single symbol, the data from Scanner A
will always appear first, and the data from Scanner B second.
Appropriate No-Read messages may be selected for each scanner by
using the No-Read Replacement Rules.
Example 2: Identifying the Source of Data
Parameter Rule #1 Value Rule #2 Value
Source A|B Aux
Symbology Any Any
Symbol Number All All
Find String Containing .* .*
Replace Entire String
With
& & Aux Data
Minimum Field Length 0 0
Alignment Right Right
Fill Character None None
Host Message Field
Number
1 1
All scanner data will be sent to the host as received. Data entered
into the AUX Port will be sent with the characters “Aux Data”
appended to the data. In a real application, it may be critical to know
the source of information. The Host Replacement Rules make this
possible. (Also see Source Identifier.)