Configuration Areas of Memory
D–4
PCCC
Address
Configuration Parameter
Number
of Bytes
(* = Default)
Acceptable Values
494h Inter–Scan Timer 2 *0 = Timer Disabled
0010 – – – 9999
496h Bar Code Type in Match Code Table Entry 1 1 0 = *Code 39
1 = Interleaved 2 of 5
2 = Codabar
3 = UPC–A
4 = UPC–E
5 = EAN–8
6 =EAN–13
7 =Code 128
497h Enable Match Code Table Entry 1 1 0 = *No
1 = Yes
498h Match Code 1) Length
Match Code 1) String
1
32
0–32, 0 = *empty
32 Characters
4B9h Output Condition 1 1 0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load
4BAh Output Pulse 1) Duration 2 *0, 10 – – – 9999
4BCh Bar Code Type in Match Code Table Entry 2 1 0 = *Code 38
1 = Interleaved 2 of 5
2 =Codabar
3 = UPC–A
4 =UPC–E
5 = EAN–8
6 = EAN–13
7 = Code 128
4BDh Enable Match Code Table Entry 2 1 0 = *No
1 = Yes
4BEh Match Code 2) Length
Match Code 2) String
1 0–32, 0 = *empty
32 Characters
4DFh Output Condition 2 1 0 = *None
1 = Read (Package)
2 = No–Read (Package)
3 = Match–Complete
4 = Match Entry
5 = Read and No–Match
6 = No–Read or No–Match
7 = Auto Load
4E0h Output Pulse 2) Duration 2 *0, 10 – – – 9999