User Manual

Interface
Chapter 7
Host Commands Using the RS-232 or RS-422
7–16
Comments: OC = Set output condition and duration command.
n = output number. This value must be from 1 through 8.
c = condition that will assert an output:0 = None
1 = Read (Package)
2 = No-Read (Package)
3 = Match-Complete
4 = Match Entry In Table
5 = Read and No Match
6 = No-Read or No-Match
7 = Auto Load
8 = Auto Load (INPUT)
(Only if n = 8)
tttt = time in milliseconds that the output will be turned on.
Value must be in the range of 0010 to 9999.
rr = response code, refer to Table 7.B.
<end> = end of message code.
Example:
Command: OC510110
Response: =00CR
Comments: 5 = specifies output #5.
1 = specifies an output with Read (Package).
0110 = sets output duration to 110 milliseconds.
00 = “command complete” response code.
CR = end of message code for Carriage Return.
Command: PC
Function: When sent, this command will clear the package count (set
to zero).
Response: =rr<end>
Comments: PC = Clear package count command.
rr = response code, refer to Table 7.B.
<end> = end of message code.
17. Clear Package Count