User guide
Table Of Contents
- Front Cover
- Important User Information
- Table of Contents
- Preface
- 1 - Scanner Features
- 2 - Installing Your Hardware
- Important Notes on Scanner Systems
- 1. Unpacking the Equipment
- 2. Setting the Address of the Base/Charger Unit
- 3. Connecting the Host Cable to the Base/Charger Unit
- 4. Mounting the Base/Charger Unit
- 5. Mounting the Power Supply
- 6. Connecting the Power Supply to the Base/Charger Unit and Power Receptacle
- 7. Connecting the Host Cable to the Host Device
- 8. Charging the Battery
- 9. Pairing the Scanner to the Base/Charger Unit
- 3 - Configuring Your Scanner
- 4 - Scanner Operation
- 5 - Maintenance and Troubleshooting
- A - Specifications
- B - Cable Pinouts
- C - Advanced Data Formatting
- Glossary
- Index
- Test Symbols
- Back Cover

5–18 Maintenance and Troubleshooting
Publication 2755-6.3
Listening for an Audible Response
When scanning a bar code symbol, you hear beeps from the scanner.
Refer to the following tables to determine the meaning of the beeps.
Beep During Normal Operation
This Response Indicates
1 Beep (short–high tone)
Bar code symbol is decoded. Scanner
audible response must be enabled.
2 Beeps (long–high tone)
Mismatch between the selected host and
interface cable.
4 Beeps (long–high tone)
Format or transmission error detected. This
error occurs if the scanner is not properly
configured. Verify option settings.
5 Beeps (long–high tone)
Data conversion error detected. This error
occurs if the Ignore Unknown Characters is
disabled when attempting to transmit data not
supported by the selected host.
6 Beeps (short–low tone)
RF out of range error detected. The scan did
not register with the base/charger unit.
Beep During Entering Parameter Bar Codes
This Response Indicates
1 Beep (short–high tone)
Bar code symbol is accepted. Scanner
audible response must be enabled.
1 Beep (low–high tone)
Input error. Possible causes:
•Incorrect bar code scanned
•Cancel scanned
•Incorrect configuration sequence
1 Beep (high–low tone)
Keyboard parameter selected. Scan the
appropriate bar code.
1 Beep (high–low–high–low tone)
Successful program exit with change in the
parameter setting.