Allen-Bradley 2-D Hand-Held Bar Code Scanners (Cat. No.
Important User Information The illustrations, charts, sample programs and layout examples shown in this guide are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Allen-Bradley does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication. Allen-Bradley publication SGI-1.
Table of Contents Preface Configuration Bar Code Symbols . . . . . . . . . . . . . . . . . . . . . . . . How to Use this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Chapter 1 P–1 P–2 Scanner Configuration Set Default Parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Select the Symbologies You Want to Enable or Disable . . . . . . . . Select Code 39 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Transmit UPC-A / UPC-E Check Digit .
toc–ii Table of Contents Chapter 2 RS-232 Synapse Cable (Communication Setup) RS-232 Synapse Cable Defaults . . . . . . . . . . . . . . . . . . . . . . . . 2–2 Fixed Format Hosts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–3 Baud Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–4 Parity Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2–5 Stop and Data Bits . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents toc–iii Chapter 5 DEC VT220/320/420 Keyboard Wedge Synapse Cable (Communication Setup) DEC VT220/320/420 Keyboard Wedge Synapse Cable Defaults . . Host . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Country Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Unknown Characters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Intercharacter Delay . . . . . . . . . . . . . . . . . . . . . . . . . . . .
toc–iv Table of Contents Appendix A Advanced Data Formatting Codes Special Commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Start/Save Rule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Erase/Quit Rule . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Disable Rule Sets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Criteria . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Table of Contents toc–v Appendix C Flexible Interface (RB) Module Application Hardware Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Scanner Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Configuration Codes for Flexible Interface Module Application . . . . Flexible Interface Module Setup . . . . . . . . . . . . . . . . . . . . . . . . . C–2 C–2 C–3 C–4 Appendix D SLC 5/03, 5/04 Application Hardware Connections . . . . . . . . . . . . . . . . .
Preface Read this First This guide provides the configuration bar codes for the following: • 2-D Hand-Held Bar Code Scanners • • • • (Catalog No. 2755-HTG-4) RS-232 Synapse Cables (Catalog No. 2755-HFC-SR2-01, 2755-HFC-SR3-01) IBM or Compatible Keyboard Wedge Synapse Cables (Catalog No. 2755-HFC-SP1-01, 2755-HFC-SP2-01) DEC Keyboard Wedge Synapse Cables (Catalog No. 2755-SV1–01, 2755-SV2-01) Scanner Emulation Synapse Cable (Catalog No.
P–2 Preface How to Use this Guide The following shows a typical sequence for configuring a scanner. 1. Connect scanner to host and apply power. 2. Configure scanner. 3. Configure communications.
Chapter 1 Scanner Configuration Set Default Parameters Scan the following labels to set the scanner to default settings. The table on the next page lists the defaults. Set Defaults Publication 2755-6.
1–2 Scanner Configuration The scanner is now set to these defaults: Scanner Configuration Parameters Default Setting Set Default Parameters Symbologies Code on Page: 1–1 All Enabled 1–3 Code 39 Full ASCII Enabled 1–6 Transmit Code 39 Check Digit Enabled 1–6 Transmit UPC-A Check Digit Enabled 1–7 Transmit UPC-E Check Digit Enabled 1–7 Convert UPC-E to UPC-A Disabled 1–7 Decode UPC / EAN Supplements Disabled 1–8 Convert EAN-8 to EAN-13 Disabled 1–9 UPC-A Preamble System Character
Scanner Configuration 1–3 Select The Symbologies You Want to Enable or Disable Enable Code 39* Disable Code 39 Enable UPC-A* Disable UPC-A Enable UPC-E* Disable UPC-E Publication 2755-6.
1–4 Scanner Configuration Enable Codabar Disable Codabar* Enable EAN 8* Disable EAN 8 Enable EAN 13* Disable EAN 13 Publication 2755-6.
Scanner Configuration 1–5 Select The Symbologies You Want to Enable or Disable Enable Interleaved 2 of 5 Disable Interleaved 2 of 5* Enable UCC/EAN-128* Disable UCC/EAN-128 Enable Code 128* Enable Code 128* Disable Code 128 Note: The scanner is always enabled to read Code 128 configuration codes. Publication 2755-6.
1–6 Scanner Configuration Enable PDF417 * Disable PDF417 Select Code 39 Options Enable Code 39 Full ASCII* Disable Code 39 Full ASCII Enable Code 39 Check Digit* Disable Code 39 Check Digit Publication 2755-6.
Scanner Configuration 1–7 Transmit UPC-A / UPC-E Check Digit Transmit UPC-A Check Digit* Do Not Transmit UPC-A Check Digit Transmit UPC-E Check Digit* Do Not Transmit UPC-E Check Digit Convert UPC-E to UPC-A Convert UPC-E to UPC-A Do Not Convert UPC-E to UPC-A* Publication 2755-6.
1–8 Scanner Configuration Decode UPC / EAN Supplements Decode UPC / EAN Supplemental Ignore UPC / EAN With Supplementals* Autodiscriminate UPC / EAN with Supplementals Convert EAN-8 to EAN-13 Convert EAN-8 to EAN-13 Disable Convert EAN-8 to EAN-13* Publication 2755-6.
Scanner Configuration 1–9 Select UPC-A Preamble No UPC-A Preamble UPC-A System Character Preamble* UPC-A System Character and Country Code Preamble Select UPC-E Preamble No UPC-E Preamble UPC-E System Character Preamble* UPC-E System Character and Country Code Preamble Publication 2755-6.
1–10 Scanner Configuration Select Code 39 – Code Lengths Code 39 Any Length Code 39 Length Within Range (Range 01-55*) Code 39 – One Discrete Length (Range 01-55) Default is None Code 39 – Two Discrete Lengths (Range 01-55) Default is None Publication 2755-6.
Scanner Configuration 1–11 Select Codabar Code Lengths Codabar Any Length Codabar Length Within Range (Range 01-55) Default is 02 –55 Codabar – One Discrete Length (Range 01-55) Default is None Codabar – Two Discrete Lengths (Range 01-55) Default is None Publication 2755-6.
1–12 Scanner Configuration Select Interleaved 2 of 5 Code Lengths Interleaved 2 of 5 Any Length Interleaved 2 of 5 – Length Within Range (Range 02-55) Default is None Interleaved 2 of 5 – One Discrete Length (Range 02-54) Default is 14 Interleaved 2 of 5 – Two Discrete Lengths (Range 02-54) Default is None Publication 2755-6.
Scanner Configuration 1–13 Scan 2 Digit Code Length 0 1 2 3 4 5 6 7 8 9 Cancel (Clears Code Length) Publication 2755-6.
1–14 Scanner Configuration Select Prefix/Suffix Options To set a suffix or prefix, scan the appropriate label below and then scan the 4 digit ASCII equivalent for the character you want to use as the prefix or suffix. See the ASCII Chart in Appendix G. Prefix Suffix Publication 2755-6.
Scanner Configuration 1–15 Prefix/Suffix – 4 Digit ASCII Equivalent Value 0 1 2 3 4 5 6 7 8 9 Cancel (Clears Code Length) Publication 2755-6.
1–16 Scanner Configuration Data Transmission Format Scan this Symbol First Send As Is* (No Prefix or Suffix) Send Send Send Scan Enter after Scanning Option Cancel Publication 2755-6.
Scanner Configuration 1–17 Transmit No-Read Message Send NR Message When Symbol Does Not Decode Do Not Send NR Message Transmit LRC Checksum Enable LRC Checksum Disable LRC Checksum Publication 2755-6.
1–18 Scanner Configuration Transmit Code ID Character Transmit Symbol Code ID Character Transmit AIM Code ID Character Do Not Transmit Code ID Character Publication 2755-6.
Scanner Configuration 1–19 Beeper After Good Decode / Beeper Tone Beep After Good Decode* Do Not Beep After Good Decode Low Tone Medium Tone High Tone Decode Buffering Enable Decode Buffering Disable Decode Buffering Publication 2755-6.
1–20 Scanner Configuration Pause Duration Enter a Pause Duration Default is 0.0 Seconds Decode Attempt Duration Enter a Decode Atttempt Duration Default is 5.0 seconds Publication 2755-6.
Scanner Configuration 1–21 Pause/Decode Attempt Duration Values 0 1 2 3 4 5 6 7 8 9 Cancel Publication 2755-6.
1–22 Scanner Configuration Smart Raster Enable Smart Raster* Disable Smart Raster Hand-Held Options Slab Raster* Aiming Dot (Normal Timeout) Enable Always Raster Publication 2755-6.
Chapter 2 RS-232 Synapse Cable (Communication Setup) This chapter provides the configuration bar codes for the following RS-232 Synapse cables: • (Catalog No. 2755-HFC-SR2-01) • (Catalog No. 2755-HFC-SR3-01) Publication 2755-6.
2–2 RS-232 Synapse Cable Set RS-232 Synapse Cable Defaults Scan this label to set the default settings for the RS-232 Synapse cable. Defaults are indicated with an asterisk. Set RS-232 Synapse Cable Defaults Scan this label to set the RS-232 Synapse cable to the default settings shown below.
RS-232 Synapse Cable 2–3 RS-232 Synapse Cable Fixed Format Hosts Currently only one option for fixed format hosts is available. Scan the Standard RS-232 host bar code symbol. Additional hosts may be added at a future date. Standard RS-232 * Publication 2755-6.
2–4 RS-232 Synapse Cable RS-232 Synapse Cable Baud Rate 110 300 600 1200 2400 4800 9600 * 19200 Publication 2755-6.
RS-232 Synapse Cable 2–5 RS-232 Synapse Cable Parity Options None * Odd Even Mark Space Check Parity* Do Not Check Parity Publication 2755-6.
2–6 RS-232 Synapse Cable RS-232 Synapse Cable Stop and Data Bits One Stop Bit * Two Stop Bits 8 Data Bits * 7 Data Bits Publication 2755-6.
RS-232 Synapse Cable 2–7 RS-232 Synapse Cable Hardware Handshaking No Hardware Handshaking* RTS / CTS Enable RTS Low * RTS High Publication 2755-6.
2–8 RS-232 Synapse Cable RS-232 Synapse Cable Software Handshaking No Software Handshaking* ACK / NAK ENQ Only ACK / NAK with ENQ XON / XOFF Publication 2755-6.
RS-232 Synapse Cable 2–9 RS-232 Synapse Cable Beep On Do Not Beep on * Beep on RS-232 Synapse Cable Unknown Characters Send Bar Codes with Unknown Characters * Do Not Send Bar Codes with Unknown Characters Publication 2755-6.
2–10 RS-232 Synapse Cable RS-232 Synapse Cable Response Timeout Scan the following symbol followed by the two digit timeout from 0.0 to 9.9 (default is 2.0 seconds). Enter Response Timeout 0 1 2 3 4 Publication 2755-6.
RS-232 Synapse Cable 2–11 5 6 7 8 9 Cancel (Clears Entry) Publication 2755-6.
2–12 RS-232 Synapse Cable RS-232 Synapse Cable Advanced Features Scan the following symbols to select the current parameter set and/or set the defaults for each parameter set. Parameter Set 1 * Parameter Set 2 Set Cable Defaults Current Parameter Set Set Cable Defaults Both Parameter Sets Publication 2755-6.
Chapter 3 IBM Keyboard Wedge (Communication Setup) This chapter provides the configuration bar codes for the IBM Keyboard Wedge Synapse cables: • (Catalog No. 2755-HFC-SP1-01) • (Catalog No. 2755-HFC-SP2-01) IBM Keyboard Wedge Synapse Cable Defaults Scan the following bar code to set the IBM Keyboard Wedge Cables to their default values. Defaults are indicated with an asterisk *.
3–2 IBM Keyboard Wedge IBM Keyboard Wedge Cable Host IBM PC / AT * IBM PS/2-50, 55SX, 60, 70,80 IBM PC / XT IBM PS/2-30 NCR 7052 Publication 2755-6.
IBM Keyboard Wedge 3–3 IBM Keyboard Wedge Country Selection North American * German French French International Spanish Italian Swedish British Publication 2755-6.
3–4 IBM Keyboard Wedge IBM Keyboard Wedge Unknown Characters Send Bar Codes with Unknown Characters * Do Not Send Bar Codes with Unknown Characters IBM Keyboard Wedge Intercharacter Delay Short 5 Millisecond Delay * Medium 50 Millisecond Delay Long 99 Millisecond Delay Publication 2755-6.
IBM Keyboard Wedge 3–5 IBM Keyboard Wedge Cable Advanced Features Parameter Set 1 * Parameter Set 2 Set Cable Defaults Current Parameter Set Set Cable Defaults Both Parameter Sets Publication 2755-6.
Chapter 4 DEC VT520 Keyboard Wedge (Communication Setup) This chapter provides the configuration bar codes for the DEC keyboard Synapse cable: • (Catalog No. 2755-HFC-SV2-01) DEC VT520 Keyboard Wedge Synapse Cable Defaults Scan the following bar code to set the IBM Keyboard Wedge Cables to their default values. Defaults are indicated with an asterisk. Set DEC VT520 Keyboard Wedge Synapse Cable Defaults Scan this label to set the DEC VT520 Synapse cable to the default settings shown below.
4–2 DEC VT520 Keyboard Wedge DEC VT520 Wedge Synapse Cable Host DEC VT520 * DEC VT520 with PS/2 Keyboard DEC VT520 Keyboard Wedge Country Selection North American * German Publication 2755-6.
DEC VT520 Keyboard Wedge 4–3 French French International Spanish Italian Swedish British Publication 2755-6.
4–4 DEC VT520 Keyboard Wedge DEC VT520 Cable Unknown Characters Send Bar Codes with Unknown Characters * Do Not Send Bar Codes with Unknown Characters DEC VT520 Keyboard Wedge Intercharacter Delay Short 5 Millisecond Delay * Medium 50 Millisecond Delay Long 99 Millisecond Delay Publication 2755-6.
DEC VT520 Keyboard Wedge 4–5 DEC VT520 Keyboard Wedge Synapse Cable Advanced Features Scan the following symbols to select the current parameter set and/or set the defaults for each parameter set. Parameter Set 1 * Parameter Set 2 Set Cable Defaults Current Parameter Set Set Cable Defaults Both Parameter Sets Publication 2755-6.
Chapter 5 DEC VT220/320/420 Keyboard Wedge Cable (Communication Setup) This chapter provides the configuration bar codes for the DEC VT220/320/420 keyboard wedge Synapse cable: • (Catalog No. 2755-HFC-SV1-01) DEC VT220/320/420 Keyboard Wedge Interface Cable Defaults Scan the following bar code to set the DEC VT220/320/420 Keyboard Wedge Cables to their default values. Defaults are indicated with an asterisk *.
5–2 DEC VT220/320/420 DEC VT220 / 320 / 420 Keyboard Wedge Synapse Cable Host DEC VT220 / 320 * DEC VT420 DEC VT220 / 320 / 420 Keyboard Wedge Country Selection North American * German Publication 2755-6.
DEC VT220/320/420 5–3 French French International Spanish Italian Swedish British Publication 2755-6.
5–4 DEC VT220/320/420 DEC VT220/320/420 Keyboard Wedge Unknown Characters Send Bar Codes with Unknown Characters * Do Not Send Bar Codes with Unknown Characters DEC VT220/320/420 Keyboard Wedge Intercharacter Delay Short 5 Millisecond Delay * Medium 50 Millisecond Delay Long 99 Millisecond Delay Publication 2755-6.
DEC VT220/320/420 5–5 DEC VT220/320/420 Keyboard Wedge Advanced Features Scan the following symbols to select the current parameter set and/or set the defaults for each parameter set. Parameter Set 1 * Parameter Set 2 Set Cable Defaults Current Parameter Set Set Cable Defaults Both Parameter Sets Publication 2755-6.
Chapter 6 Scanner Emulation Cable (Communication Setup) This chapter provides the configuration bar codes for the scanner emulation Synapse cable: • (Catalog No. 2755-HFC-SA1-01) Scanner Emulation Synapse Cable Defaults Scan the following bar code to set the scanner emulation cable to its default values. Defaults are indicated with an asterisk *. Set Scanner Emulation Cable Defaults Scan this label to set the Scanner Emulation Synapse cable to the default settings shown below.
6–2 Scanner Emulation Cable Scanner Emulation Host Standard Wand Emulation * MSI Wand Emulation Telxon Wand Emulation Norand Wand Emulation Publication 2755-6.
Scanner Emulation Cable 6–3 Scanner Emulation Variable Leading Margin 80 Millisecond * 140 Millisecond 200 Millisecond Scanner Emulation Check for Decode LED Check for Decode LED * Do Not Check for Decode LED Publication 2755-6.
6–4 Scanner Emulation Cable Scanner Emulation Timeout 3 Second Timeout * 4 Second Timeout 5 Second Timeout 10 Second Timeout 30 Second Timeout Publication 2755-6.
Scanner Emulation Cable 6–5 Scanner Emulation Polarity Margin Low / Bar High * Margin High / Bar Low Send Bar Codes with Unknown Characters Send Bar Codes with Unknown Characters * Do Not Send Bar Codes with Unknown Characters Publication 2755-6.
6–6 Scanner Emulation Cable Scanner Emulation Convert All to Code 39 Do Not Convert All to Code 39 * Convert All to Code 39 Scanner Emulation Code 39 to Code 39 Full ASCII Do Not Do Not Convert Code 39 to Code 39 Full ASCII * Convert Code 39 to Code 39 Full ASCII Publication 2755-6.
Scanner Emulation Cable 6–7 Scanner Emulation Cable Advanced Features Scan the following symbols to select the current parameter set and/or set the defaults for each parameter set. Parameter Set 1 * Parameter Set 2 Set Cable Defaults Current Parameter Set Set Cable Defaults Both Parameter Sets Publication 2755-6.
Appendix A ADF Bar Codes This Appendix contains all of the bar codes for Advanced Data Formatting (ADF). The table below lists the group of ADF codes and their corresponding page numbers. See Appendix E in the Scanner Configuration manual for a description of the ADF codes.
A–2 ADF Bar Codes Special Commands – Start/Save Rules Start New Rule Save Rule Publication 2755-6.
ADF Bar Codes A–3 Special Commands – Erase/Quit Rules Erase Criteria and Start Again Erase Actions and Start Again Quit Entering Rules Erase Previously Saved Rule Erase All Rules Publication 2755-6.
A–4 ADF Bar Codes Special Commands – Disable Rule Sets Disable Rule Set 1 Disable Rule Set 2 Disable Rule Set 3 Disable Rule Set 4 Disable All Rule Sets Publication 2755-6.
ADF Bar Codes A–5 Criteria – Code Types You must scan code types before scanning other criteria. Code 39 Codabar Code 128 Interleaved 2 of 5 EAN 128 Publication 2755-6.
A–6 ADF Bar Codes Criteria – Code Types You must scan code types before scanning other criteria. UPC-A UPC-E EAN-8 EAN-13 PDF417 Publication 2755-6.
ADF Bar Codes A–7 Criteria – Code Lengths This is not a keypad. Select one length per rule. 1 2 3 4 5 6 7 8 9 10 Publication 2755-6.
A–8 ADF Bar Codes Criteria – Code Lengths 11 12 13 14 15 16 17 18 19 20 Publication 2755-6.
ADF Bar Codes A–9 Criteria – Code Lengths 21 22 23 24 25 26 27 28 29 30 Publication 2755-6.
A–10 ADF Bar Codes Criteria – Specific Data String Specific String at Start 1. Go to Alphanumeric Keyboard (page A–49) to enter string 2. Scan End of Message bar code (page A–56). Specific String Any Location 1. Scan 2-digit length on Numeric Keypad (page A–11) to enter location. 2. Go to Alphanumeric Keyboard (page A–49) to enter string. 2. Scan End of Message bar code (page A–56). Publication 2755-6.
ADF Bar Codes A–11 Criteria – Numeric Keypad 0 1 2 3 4 5 6 7 8 9 Cancel Publication 2755-6.
A–12 ADF Bar Codes Criteria – Specific Data String Send Up to Character ➀ Note: If there is no match when the rule is interpreted and the rule fails, the next rule is checked. Move to Character ➀ Note: If there is no match when the rule is interpreted and the rule fails, the next rule is checked. Move Past Character ➀ ➀ Enter character using AlphaNumeric Keyboard (page A–49). Publication 2755-6.
ADF Bar Codes A–13 Criteria – Rules Belongs to Sets Rule Belongs to Set 1 Rule Belongs to Set 2 Rule Belongs to Sets 3 Rule Belongs to Set 4 Publication 2755-6.
A–14 ADF Bar Codes Actions – Send Characters / Data Send Pause Send All Remaining Data Send Next Character Send Next 2 Characters Send Next 3 Characters Send Next 4 Characters Send Next 5 Characters Send Next 6 Characters Send Next 7 Characters Publication 2755-6.
ADF Bar Codes A–15 Actions – Send Characters / Data Send Next 8 Characters Send Next 9 Characters Send Next 10 Characters Send Next 11 Characters Send Next 12 Characters Send Next 13 Characters Publication 2755-6.
A–16 ADF Bar Codes Actions – Send Characters / Data Send Next 14 Characters Send Next 15 Characters Send Next 16 Characters Send Next 17 Characters Send Next 18 Characters Send Next 19 Characters Publication 2755-6.
ADF Bar Codes A–17 Actions – Send Characters / Data Send Next 20 Characters Send Next 50 Characters Send Next 100 Characters Send Next 150 Characters Send Next 200 Characters Send Next 250 Characters Publication 2755-6.
A–18 ADF Bar Codes Actions – Skip Ahead / Back Skip Ahead 1 Character Skip Ahead 2 Characters Skip Ahead 3 Characters Skip Ahead 4 Characters Skip Ahead 5 Characters Skip Ahead 6 Characters Skip Ahead 7 Characters Skip Ahead 8 Characters Publication 2755-6.
ADF Bar Codes A–19 Actions – Skip Ahead / Back Skip Ahead 9 Characters Skip Ahead 10 Characters Skip Ahead 50 Characters Skip Ahead 100 Characters Skip Ahead 150 Characters Skip Ahead 200 Characters Skip Ahead 250 Characters Publication 2755-6.
A–20 ADF Bar Codes Actions – Skip Ahead / Back Skip Back 1 Character Skip Back 2 Characters Skip Back 3 Characters Skip Back 4 Characters Skip Back 5 Characters Skip Back 6 Characters Skip Back 7 Characters Skip Back 8 Characters Publication 2755-6.
ADF Bar Codes A–21 Actions – Skip Ahead / Back Skip Back 9 Characters Skip Back 10 Characters Skip Back 50 Characters Skip Back 100 Characters Skip Back 150 Characters Skip Back 200 Characters Skip Back 250 Characters Skip to Start of Data Publication 2755-6.
A–22 ADF Bar Codes Actions – Spaces and Zeross Remove All Spaces Crunch All Spaces Stop Space Removal Remove Leading Zeroes Stop Zero Removal Publication 2755-6.
ADF Bar Codes A–23 Actions – Send Value Send Value 1 Send Value 2 Publication 2755-6.
A–24 ADF Bar Codes Actions – Beeps Beep Once ➀ Beep Twice ➁ Beep Three Times ➁ ➁ Choose only one beep sequence per AFD Rule Publication 2755-6.
ADF Bar Codes A–25 Actions – Pad Spaces Pad Spaces to Length 1 Pad Spaces to Length 2 Pad Spaces to Length 3 Pad Spaces to Length 4 Pad Spaces to Length 5 Pad Spaces to Length 6 Pad Spaces to Length 7 Pad Spaces to Length 8 Publication 2755-6.
A–26 ADF Bar Codes Actions – Pad Spaces Pad Spaces to Length 9 Pad Spaces to Length 10 Pad Spaces to Length 11 Pad Spaces to Length 12 Pad Spaces to Length 13 Pad Spaces to Length 14 Pad Spaces to Length 15 Pad Spaces to Length 16 Publication 2755-6.
ADF Bar Codes A–27 Actions – Pad Spaces Pad Spaces to Length 17 Pad Spaces to Length 18 Pad Spaces to Length 19 Pad Spaces to Length 20 Pad Spaces to Length 21 Pad Spaces to Length 22 Pad Spaces to Length 23 Pad Spaces to Length 24 Publication 2755-6.
A–28 ADF Bar Codes Actions – Pad Spaces Pad Spaces to Length 25 Pad Spaces to Length 26 Pad Spaces to Length 27 Pad Spaces to Length 28 Pad Spaces to Length 29 Pad Spaces to Length 30 Stop Pad Spaces Publication 2755-6.
ADF Bar Codes A–29 Actions – Pad Zeros Pad Zeros to Length 1 Pad Zeros to Length 2 Pad Zeros to Length 3 Pad Zeros to Length 4 Pad Zeros to Length 5 Pad Spaces to Length 6 Pad Spaces to Length 7 Pad Spaces to Length 8 Publication 2755-6.
A–30 ADF Bar Codes Actions – Pad Zeros Pad Zeros to Length 9 Pad Zeros to Length 10 Pad Zeros to Length 11 Pad Zeros to Length 12 Pad Zeros to Length 13 Pad Spaces to Length 14 Pad Spaces to Length 15 Pad Spaces to Length 16 Publication 2755-6.
ADF Bar Codes A–31 Actions – Pad Zeros Pad Zeros to Length 17 Pad Zeros to Length 18 Pad Zeros to Length 19 Pad Zeros to Length 20 Pad Zeros to Length 21 Pad Spaces to Length 22 Pad Spaces to Length 23 Pad Spaces to Length 24 Publication 2755-6.
A–32 ADF Bar Codes Actions – Pad Zeros Pad Zeros to Length 25 Pad Zeros to Length 26 Pad Zeros to Length 27 Pad Zeros to Length 28 Pad Zeros to Length 29 Pad Spaces to Length 30 Stop Pad Zeros Publication 2755-6.
ADF Bar Codes A–33 Actions – Send Control Characters Send Control 2 Send Control A Send Control B Send Control C Send Control D Send Control E Send Control F Send Control G Publication 2755-6.
A–34 ADF Bar Codes Actions – Send Control Characters Send Control H Send Control I Send Control J Send Control K Send Control L Send Control M Send Control N Send Control O Publication 2755-6.
ADF Bar Codes A–35 Actions – Send Control Characters Send Control P Send Control Q Send Control R Send Control S Send Control T Send Control U Send Control V Send Control W Publication 2755-6.
A–36 ADF Bar Codes Actions – Send Control Characters Send Control X Send Control Y Send Control Z Send Control [ Send Control \ Send Control ] Send Control 6 Send Control – Publication 2755-6.
ADF Bar Codes A–37 Actions – Send Keyboard Characters Send Space Send ! Send “ Send # Send $ Send % Send & Send ‘ Publication 2755-6.
A–38 ADF Bar Codes Actions – Keyboard Characters Send ( Send ) Send * Send + Send , Send - Send . Send / Publication 2755-6.
ADF Bar Codes A–39 Actions – Send Keyboard Characters Send 0 Send 1 Send 2 Send 3 Send 4 Send 5 Send 6 Send 7 Publication 2755-6.
A–40 ADF Bar Codes Actions – Send Keyboard Characters Send 8 Send 9 Send : Send ; Send < Send = Send > Send ? Publication 2755-6.
ADF Bar Codes A–41 Actions – Send Keyboard Characters Send @ Send A Send B Send C Send D Send E Send F Send G Publication 2755-6.
A–42 ADF Bar Codes Actions – Send Keyboard Characters Send H Send I Send J Send K Send L Send M Send N Send O Publication 2755-6.
ADF Bar Codes A–43 Actions – Send Keyboard Characters Send P Send Q Send R Send S Send T Send U Send V Send W Publication 2755-6.
A–44 ADF Bar Codes Actions – Send Keyboard Characters Send X Send Y Send Z Send [ Send \ Send ] Send ^ Send _ Publication 2755-6.
ADF Bar Codes A–45 Actions – Send Keyboard Characters Send ‘ Send a Send b Send c Send d Send e Send f Send g Publication 2755-6.
A–46 ADF Bar Codes Actions – Send Keyboard Characters Send h Send i Send j Send k Send l Send m Send n Send o Publication 2755-6.
ADF Bar Codes A–47 Actions – Send Keyboard Characters Send p Send q Send r Send s Send t Send u Send v Send w Publication 2755-6.
A–48 ADF Bar Codes Actions – Send Keyboard Characters Send x Send y Send z Send { Send | Send } Send – Publication 2755-6.
ADF Bar Codes A–49 Actions – AlphaNumeric Keyboard SPACE # $ % * + - . Publication 2755-6.
A–50 ADF Bar Codes Actions – AlphaNumeric Keyboard / ! “ & ‘ ( ) : Publication 2755-6.
ADF Bar Codes A–51 Actions – AlphaNumeric Keyboard ; < = > ? @ [ \ Publication 2755-6.
A–52 ADF Bar Codes Actions – AlphaNumeric Keyboard ] ^ – ‘ Publication 2755-6.
ADF Bar Codes A–53 Actions – AlphaNumeric Keyboard Do not confuse these bar codes with those on the numeric keypad. 0 1 2 3 4 5 6 7 8 9 Publication 2755-6.
A–54 ADF Bar Codes Actions – AlphaNumeric Keyboard A B C D E F G H I J Publication 2755-6.
ADF Bar Codes A–55 Actions – AlphaNumeric Keyboard K L M N O P Q R S T Publication 2755-6.
A–56 ADF Bar Codes Actions – AlphaNumeric Keyboard U V W X Y Z CANCEL END OF MESSAGE Publication 2755-6.
ADF Bar Codes A–57 Actions – AlphaNumeric Keyboard a b c d e f g h i j Publication 2755-6.
A–58 ADF Bar Codes Actions – AlphaNumeric Keyboard k l m n o p q r s t Publication 2755-6.
ADF Bar Codes A–59 Actions – AlphaNumeric Keyboard u v w x y z { | } ~ Publication 2755-6.
A–60 ADF Bar Codes Actions – Turn of Rule Set Turn on Rule Set 1 Turn on Rule Set 2 Turn on Rule Set 3 Turn on Rule Set 4 Turn off Rule Set 1 Turn off Rule Set 2 Turn off Rule Set 3 Turn off Rule Set 4 Publication 2755-6.
Appendix B Enhanced Decoder Application This appendix describes how to configure and operate the scanner when connected to an Allen-Bradley Enhanced Decoder (Catalog No. 2755-DD/DS). • using the RS-232 port for output • using the AUX port for Pass-Through This section also provides configuration information for an Auxiliary Port Pass Through application for the enhanced decoder.
B–2 Enhanced Decoder Application Enhanced Decoder Application using Scanner Port Hardware Connections for Scanner Output The scanner connects to an input port on the Enhanced Decoder with a Scanner Emulation Synapse cable (Catalog No. 2755-HFC-SA1-01) and Gun Adapter (Catalog No. 2755-NC16). Power Supply Scanner Cable Scanner Scanner Emulation Synapse Cable (2755-HFC-SA1-01) Note: The power supply should be connected last. Gun Adapter (Catalog No.
Enhanced Decoder Application B–3 Configuration Codes for Scanner Emulation Output 1. After making the necessary connections, scan the following following bar code symbol to set the scanner to its default settings. Set Scanner Defaults 2. Set the scanner emulation cable to defaults by scanning the following: Set Scanner Cable Defaults 3. The Scanner Emulation Synapse cable defaults will work with the enhanced decoder. Your application may have specific requirements.
B–4 Enhanced Decoder Application Enhanced Decoder Setup for Scanner Input You will need to configure the Allen-Bradley Enhanced decoder. Refer to the Enhanced Decoder user manual (Publication 2755-833). 1. Set Response Mode = Valid Package 2. Set Package Detect Input Filter = Yes; Sense = Lo = Package 3. Set Laser On Mode = Triggered 4. Set Decode Trigger = Package Detect 5. No Read Timer ^ 8000 ms Publication 2755-6.
Enhanced Decoder Application B–5 Enhanced Decoder Application using AUX Port for Pass Through Hardware Connections for AUX Port Pass-Through The scanner connects to an input port on the Enhanced Decoder with a 25-pin RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01) and a null modem adapter. Scanner Cable Power Supply Scanner 25-pin RS-232 Synapse Cable (2755-HFC-SR2-01) Note: The power supply should be connected last.
B–6 Enhanced Decoder Application Configuration Codes for AUX Port Pass Through 1. After making the necessary connections, scan the following following bar code symbol to set the scanner to its default settings. Set Scanner Defaults 2. Set the RS-232 Synapse cable to defaults by scanning the following: Set RS-232 Synapse Cable Defaults 3. Set No Parity. Do Not Check Parity Publication 2755-6.
Enhanced Decoder Application B–7 Enhanced Decoder Setup for AUX Port Pass Through You will need to configure the Allen-Bradley Enhanced decoder. Refer to the Enhanced Decoder user manual (Publication 2755-833). 1. Select Aux Terminal Data Entry (Screen 8) from the Main Menu. 2. Set Enable Keyboard Entry = Yes 3. Save and Exit the configuration. 4. Move internal selector (jumper) to the data entry position on the system board (B-5, B-6). 5.
Appendix C Flexible Interface Module Application This appendix describes how to configure and operate the scanner when connected to a Flexible Interface Module (Catalog No. 2760-RB). ! ATTENTION: Do not install the RS-232 Synapse cable with power applied to either the Synapse cable or Flexible Interface Module. Failure to follow this caution may result in damage to the scanner, Synapse cable, or Flexible Interface Module.
C–2 Flexible Interface Module Application Hardware Connections The scanner connects to one of the three communication ports on the Flexible Interface Module with an RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01). The interface module requires an SFC2 Protocol Cartridge. Power Supply Scanner Cable RS-232 Synapse Cable (2755-HFC-SR2-01) Note: The power supply should be connected last.
Flexible Interface Module Application C–3 Configuration Codes for Flexible Interface Module Application 1. After making the necessary connections, scan the following following bar code symbol to set the scanner to its default settings. Set Scanner Defaults 2. Set the RS-232 Synapse cable to defaults by scanning the following: Set RS-232 Synapse Cable Defaults 3. The cable defaults will work with the Flexible Interface Module. Your application may have specific requirements.
C–4 Flexible Interface Module Application Flexible Interface Module Setup You will need to configure the Flexible Interface Module. Refer to the user manual for the protocol cartridge and interface module. 1. When configuring the Flexible Interface Module, first select 90B to reset the configuration to factory defaults. 2. Configure screens 3, 21, and 11 (in this order) as shown on the following pages: Publication 2755-6.
Flexible Interface Module Application C–5 2760–RB SERIES A REVISION J COPYRIGHT 1989 ALLEN–BRADLEY COMPANY, INC.
C–6 Flexible Interface Module Application ENTER A MAIN MENU SELECTION: 21 DUMB TERM. UNSPECIFIED PROTOCOL, 13fh (YES/NO) = YES. EDIT THIS SELECTION (YES/NO) ? ENTER A MAIN MENU SELECTION: 11 MODEM CONTROL (ENABLE/DISABLE) = DISABLE. 9600 BITS PER SECOND (YES/NO) = YES. 8 BITS NO PARITY (YES/NO) = YES. XON/XOFF (ENABLE/DISABLE) = DISABLE. RS232 (YES/NO) = YES. RECEIVE MATRIXING (ENABLE/DISABLE) = DISABLE. BYTE SWAPPING (ENABLE/DISABLE) = ENABLE. BINARY DATA NO CONVERSIONS (YES/NO) = YES.
Appendix D SLC 5/03, 5/04 Controller Application This appendix describes how to configure and operate the scanner when connected to an SLC 5/03, 5/04 controller. ! ATTENTION: Do not install the RS-232 Synapse cable with power applied to either the Synapse cable or SLC controller. Failure to follow this caution may result in damage to the scanner, Synapse cable, or SLC.
D–2 SLC 5/03, 5/04 Controller Application Hardware Connections The scanner connects to the Channel 0 port of the SLC with an RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01). Scanner Scanner Cable Power Supply RS-232 Synapse Cable (2755-HFC-SR3-01) Note: The power supply should be connected last. SLC 5/04 To Channel 0 Port Channel 0 Scanner Configuration Configure the scanner using the bar codes described in Chapter 1. The SLC controller does not require any specific scanner configuration.
SLC 5/03, 5/04 Controller Application D–3 Configuration Codes for SLC Application 1. After making the necessary connections, scan this symbol to set the scanner to its default settings. Set Scanner Defaults 2. Set the bar code suffix to CR LF (ASCII equivalent 7013) by scanning the following labels. Suffix 7 1 0 3 Publication 2755-6.
D–4 SLC 5/03, 5/04 Controller Application 3. Send the data then the suffix by scanning these labels. Scan this Symbol First Send Scan Enter after Scanning Option 4. Set the RS-232 Synapse cable to defaults by scanning the following: Set RS-232 Synapse Cable Defaults 5. The cable defaults will work with the SLC 5/03, 5/04. Your application may have specific requirements. Chapter 3 lists the settings that can be modified.
SLC 5/03, 5/04 Controller Application D–5 SLC 5/03, 5/04 Setup You will need to configure the SLC, refer to the user manuals and following instructions: 1. Set the SLC Channel 0 to User in the Channel 0 Configuration screen Publication 2755-6.
D–6 SLC 5/03, 5/04 Controller Application 2. Configure Channel 0 in the Channel 0 User Mode Configuration screen. Note that Termination 1 is set for \a or Line Feed [LF], and Termination 2 is set for \d or Carriage Return [CR]. These terminators, along with the ARL instruction in the SLC, allow you to read one message at a time with [CR] [LF] terminators. Publication 2755-6.
SLC 5/03, 5/04 Controller Application D–7 SLC Program The sample ladder logic listing below instructs the SLC 5/03 or 5/04 to: Rung 2:0 – Read one string of ASCII data terminated with a [CR] [LF]. Refer to the SLC 5/03 user manual for detailed information on using the SLC 5/03 or 5/04 programming software. Publication 2755-6.
Appendix E PLC-5 Controller Application This appendix describes how to configure and operate the scanner when connected to a PLC-5 controller. ! ATTENTION: Do not install the RS-232 Synapse cable with power applied to either the Synapse cable or PLC controller. Failure to follow this caution may result in damage to the scanner, Synapse cable, or PLC.
E–2 PLC-5 Controller Application Hardware Connections The scanner connects to the Channel 0 port of the PLC with an RS-232 Synapse cable (Catalog No. 2755-HFC-SR2-01). The connections are shown in the scanner user manual (Publication 2755-6.2). Scanner Power Supply Scanner Cable RS-232 Synapse Cable (2755-HFC-SR2-01) Note: The power supply should be connected last. PLC-5 To Channel 0 Port Scanner Configuration Configure the scanner using the bar codes described in Chapter 1.
PLC-5 Controller Application E–3 Configuration Codes for PLC Application 1. After making the necessary connections, scan the following following bar code symbol to set the scanner to its default settings. Set Scanner Defaults 2. Set the RS-232 Synapse cable to defaults by scanning this label. Set RS-232 Synapse Cable Defaults 3. Set the bar code suffix to CR LF (ASCII equivalent 7013) by scanning the following labels. Suffix 7 1 0 3 Publication 2755-6.
E–4 PLC-5 Controller Application 4. Send the data then the suffix by scanning these labels. Scan this Symbol First Send Scan Enter after Scanning Option 5. The cable defaults will work with the PLC-5. Your application may have specific requirements. Chapter 3 lists the settings that can be modified. If you change a communication setting, make sure the PLC controller is configured to accept the change. Publication 2755-6.
PLC-5 Controller Application E–5 PLC-5 Setup You will need to configure the Channel 0 port of the PLC-5. Refer to the 6200 Series Programming Software user manual and the following instructions. 1. Set the PLC-5 Channel 0 to User in the Channel 0 Configuration screen. Publication 2755-6.
E–6 PLC-5 Controller Application 2. Configure Channel 0 in the User Mode Channel 0 Configuration screen. Note that Termination 1 is set for \0xa or Line Feed [LF], and Termination 2 is set for \0xd or Carriage Return [CR]. These terminators, along with the ARL instruction in the PLC-5, allow you to read one message at a time with [CR] [LF] terminators. Publication 2755-6.
PLC-5 Controller Application E–7 PLC Program The sample ladder logic listing below instructs the PLC-5 to: Rung 2:0 – Read one string of ASCII data terminated with a [CR] [LF]. Refer to the PLC-5 user manual for detailed information on using the PLC programming software. Publication 2755-6.
Appendix F DTAMt Plus DeviceNett Application This appendix describes how to configure and operate the scanner when connected to a DTAM Plus Operator Interface on a DeviceNet network. Related Publications Below is a list of related publications you may need to refer to when using the DTAM Plus Operator Interface. Publication No. 2707-800 2707-800.
F–2 DTAMt Plus DeviceNett Application Hardware Connections The scanner connects to the DTAM Plus with the 9-Pin RS-232 Synapse cable (Catalog No. 2755-HFC-SR3-01). The cables and connections are shown in Chapter 2 of the scanner user manual (Publication 2755-6.2). PLC-5 Controller 1771-SDN Module DTAM Plus DeviceNet RS-232 Synapse Cable Publication 2755-6.
DTAMt Plus DeviceNett Application F–3 Codes for DTAM Plus Operator Interface DeviceNet Application 1. After making the necessary connections, scan the following following bar code symbol to set the scanner to its default settings. Set Scanner Defaults 2. Set the bar code suffix to CR LF (ASCII equivalent 7013) by scanning the following labels. Suffix 7 1 0 3 Publication 2755-6.
F–4 DTAMt Plus DeviceNett Application 3. Send the data then the suffix by scanning these labels. Scan this Symbol First Send Scan Enter after Scanning Option 4. Set the RS-232 Synapse cable to defaults by scanning this label. Set RS-232 Synapse Cable Defaults 5. The cable defaults will work with the DTAM Plus. Your application may have specific requirements. Chapter 3 lists the settings that can be modified.
DTAMt Plus DeviceNett Application F–5 DTAM Plus Operator Interface Setup You may need to configure the DTAM Plus Operator Interface RS-232 port to accept the scanner data. Refer to the DTAM Programming Software Programming Manual. Configure the DTAM Plus Operator Interface serial port as shown below. 1. Open Screen Builder. 2. Open Create Screen. 3. Open Data Entry Screen. 4. Select Set Up Screen. 5. Select Data Entry. 6. Select ASCII Input. 7. Set up DTAM. Publication 2755-6.
F–6 DTAMt Plus DeviceNett Application DeviceNet Operation The DTAM Plus DeviceNet operates as a Group 2 Server on the DeviceNet network. It supports the Unconnected Message Manager (UCMM). The DTAM Plus DeviceNet implements the predefined master/slave connection set, operating as a slave device. It does not initiate communications except for a Duplicate Node Address check on power-up. The DTAM Plus DeviceNet supports the polled I/O method of exchanging data with a master, in the following sequence: 1.
Appendix G ASCII Chart ASCII Value Full ASCII Code 39 Encode Char. Character (Control Code) ASCII Value Full ASCII Code 39 Encode Char.
G–2 ASCII Chart ASCII Value Full ASCII Code 39 Encode Char. Character ASCII Value Full ASCII Code 39 Encode Char. Character 1032 SP SP 1057 9 9 1033 /A ! 1058 /Z : 1034 /B ’ 1059 %F ; 1035 /C # 1060 %G < 1036 /D $ 1061 %H = 1037 /E % 1062 %I > 1038 /F & 1063 %J ? 1039 /G ’ 1064 %V @ 1040 /H ( 1065 A A 1041 /I ) 1066 B A 1042 /J * 1067 C C 1043 /K + 1068 D D 1044 /L , 1069 E E 1045 - - 1070 F F 1046 . .
ASCII Chart ASCII Value Full ASCII Code 39 Encode Char. 1082 G–3 Character ASCII Value Full ASCII Code 39 Encode Char.
G–4 ASCII Chart ALT Key Values ALT Key Value Keystroke ALT Key Value Keystroke ALT Key Value Keystroke 2064 ALT 2 2075 ALT K 2086 ALT V 2065 ALT A 2076 ALT L 2087 ALT W 2066 ALT B 2077 ALT M 2088 ALT X 2067 ALT C 2078 ALT N 2089 ALT Y 2068 ALT D 2079 ALT O 2090 ALT Z 2069 ALT E 2080 ALT P 2091 ALT [ 2070 ALT F 2081 ALT Q 2092 ALT \ 2071 ALT G 2082 ALT R 2093 ALT ] 2072 ALT H 2083 ALT S 2094 ALT 6 2073 ALT I 2084 ALT T 2095 ALT - 2074 ALT J
ASCII Chart G–5 Numeric Key Values Numeric Key Value Keystroke Numeric Key Value Keystroke Numeric Key Value Keystroke 6042 * 6049 1 6056 8 6043 + 6050 2 6057 9 6044 Undefined 6051 3 6058 Enter 6045 – 6052 4 6059 Num Lock 6046 .
TEST SYMBOLS 1 2 3 4 5 Code 128 A 1 2 3 4 Code 39 1 2 3 4 5 Code 93 B PDF-417 1 2 3 4 5 Discrete 2 of 5 1 2 3 4 5 EAN 128 1 234567 891019 EAN 13 A 1 2 3 4 B Codabar 012345 Interleaved 2 of 5 1234 5670 EAN 8 0 123456 UPC E 5 1 23456 78901 UPC A 2
Synapset is a trademark of Symbol Technologies Inc. AdaptaScant is a trademark of Allen-Bradley Worldwide representation.