Quick Start Manual User Manual

64 Publication 2711-QS003D-EN-P - June 2009
Chapter 5 Entering Application Tags
Description of the
Application Tags
DH-485, DH+, and DF1 Application Tags
The table shows application tags used by the DH-485, DH+, and DF1
applications. Defaults are accepted for fields not shown in table.
These tags are also used for EtherNet/IP (to a PLC-5E or SLC) and
ControlNet (to a PLC-5C).
Remote I/O Application Tags
The table shows application tags used by the Remote I/O application.
Defaults are accepted for fields not shown in table.
Tag Name Data Type
Tag
Address
Description
Node
Name
Initial
Value
Min Max
Start_Motor Bit B3:0/0 Starts the motor LC_1 0 0 0
Stop_Motor Bit B3:0/1 Stops the motor LC_1 0 0 0
Motor_Status_Ind Bit B3:0/2 Shows on/off motor status LC_1 0 0 0
Motor_Speed Unsigned
Integer
N7:0 Shows the motor speed LC_1 0 0 65535
Set_Max_Motor_Speed Unsigned
Integer
N7:1 Sets the maximum speed LC_1 1800 600 1800
Speed_Alarm Bit B3:1/0 Triggers alarm messages LC_1 0 0 0
Tag Name Data Type
Tag
Address
Description
Node
Name
Initial
Value
Min Max
Start_Motor Bit
I:010/0
Starts the motor LC_1 0 0 0
Stop_Motor Bit
I:010/1
Stops the motor LC_1 0 0 0
Motor_Status_Ind Bit O:010/0 Shows on/off motor status LC_1 0 0 0
Motor_Speed Unsigned
Integer
O:011 Shows the motor speed LC_1 0 0 65535
Set_Max_Motor_Speed Unsigned
Integer
I:011
Sets the maximum speed LC_1 1800 600 1800
Speed_Alarm Bit O:012/0 Triggers alarm messages LC_1 0 0 0