Operator Interface Module Instruction Manual

Special Controller Functions
Appendix C
DTAM Micro
C7
6. You can change the Acc and Pre values by pressing the [PREV] or
[NEXT] keys to move the cursor to the field to change, and then entering
a new value.
!
ATTENTION: Do not send negative timer values to the SLC.
Negative timer values cause a fault in the SLC.
7. Press the [ ] key to enter new accumulator or preset values to the
displayed timer address.
8. Press [NEXT] again to display the status bits:
File=T102 EN TT DN
Elem= 008 0 0 0
Bits
(Enable,
Timer Timing,
Done)
Status
9. To exit, press the [MODE] key to return to the initial P-A/D screen.
You can press the [MODE] key at any time during the P-A/D function.
10. Pressing the [MENU] key at the P-A/D screen exits the P-A/D function
and displays the Main Menu.