User Manual Manual

Publication 2706-UM016D-EN-P - March 2006
4-26 InView Protocol
Transmission:
Transmission for Clearing the Message Queue
Response: NONE
300 ms pause
2. Download Message #0001 to the appropriate memory position.
This stores the message in the message number used within the
data field. It overwrites any data already stored in the memory
position.
Transmission:
Download Message 1 to be Previewed
Response: NONE
300 ms pause
3. Trigger the message that was just downloaded.
Beginning
of Frame
ADDR FUNC H.O.
ADDR
L.O.
ADDR
DATA LRC
Error
EOF Ready to
rec. resp
: FF060065FFFF 98 CR LF
TIP
Messages are downloaded to register 101 (40101),
which then moves the InView message to the
appropriate memory position.
Beginning
of Frame
ADDR FUNC H.O.
ADDR
L.O.
ADDR
DATA EOF Ready to
rec. resp
: FF 01 00 64 ^AZ00^BA2001^[”b^I^^1^\1Hello^D CR LF
TIP
See section InView Display Communication Protocol
Functions and Descriptions on page 4-41 for further