InView Protocol 4-51
Set Serial Address
This command will change a serial address for a display.
Text Position Placement
Allen-Bradley uses the 2706-P42, 2706-P44, and 2706-P72 series
displays with InView industrial protocol. The displays can be single
line, two-line or 3-line. Displaying of messages using protocol is
slightly different based on which display is being used.
Below are some rules for the 2706-P44 and 2706-P72 display. The
2706-P42 display ignores the display position and show (display) the
text.
Special Function Command to Set Serial Address
<SOH> Type Code Display Address
Description ASCII Hex Description ASCII Hex Description ASCII Hex
Start of Header ^A 01 All displays Z 5A Display Address 01-FF 3031-4646
Special Function Command to Set Serial Address Continued
<STX> Command Code
Command Function
Description ASCII Hex Description ASCII Hex Description ASCII Hex
Start of Text ^B 02 Write Special Function E 45 Set address 7 37
Special Function Command to Set Serial Address Continued
Command Code (Continued) <EOT>
Serial address ASCII Hex Description ASCII Hex
New serial address 01-FE 3031-4645 End of Transmission ^D 04