USER MANUAL Manual
Remote I/O Communications 8–12
Publication 2706-6.1
The table below lists the number of separate chassis or devices the
scanner can support and how much I/O it can address.
Note: For any application, the total of all the I/O used by each device
(I/O rack, drive system, or DL40 Plus) connected to the cable gives
the number of full racks of I/O being supported by the scanner or
sub-scanner for that application.
Remote I/O Configuration
1771-SN
PLC Scanners Sub-Scanners
Processors Physical Logical Physical Logical
Mini-PLC’s
2/05
215
2/16
2/17
--- ---
16 Devices
➀
7 Racks
PLC 5/11 4 Devices 4 Racks
16 Devices
➀
7 Racks
PLC 5/12 --- ---
16 Devices
➀
7 Racks
PLC 5/15
➁
12 Devices 3 Racks
16 Devices
➀
7 Racks
PLC 5/20
➂
16 Devices 4 Racks
16 Devices
➀
7 Racks
PLC 5/25
➂
16 Devices 7 Racks
16 Devices
➀
7 Racks
PLC 5/30 28 Devices 8 Racks
16 Devices
➀
7 Racks
PLC 5/40, 5/40E
16 Devices/channel
4 Channels/scanner
15 Racks
16 Devices
➀
7 Racks
PLC 5/60, 5/60E
16 Devices/channel
4 Channels/scanner
23 Racks
16 Devices
➀
7 Racks
PLC 5/80, 5/80E
24 Devices/channel
4 Channels/scanner
32 Racks
16 Devices
➀
7 Racks
PLC 5/250 32 Devices/scanner 8 Racks/Scanner
16 Devices
➀
7 Racks
4 Scanners/processor 4 Scanners/processor
PLC 2/30 16 Devices/ channel 7 Racks total
16 Devices
➀
7 Racks
2 Channels/scanner
PLC 3 16 Devices/channel 32 Racks (64 using
16 Devices
➀
7 Racks
4 Channels/scanner complimentary I/O)
PLC 3/10 16 Devices/channel 16 Racks total
16 Devices
➀
7 Racks
4 Channels/scanner
➀
Two of these may be Bulletin 1771 chassis.
➁
PLC 5/15 Series B Revision H or later have partial rack addressing. Earlier versions were limited to
(3) devices.
➂
PLC 5/20 and 5/25 Series A Revision D or later have partial rack addressing. Earlier versions were