Using the DL50 to Display Messages from a DL40
The DL50 can receive message data from a Bulletin 2706 DL40 Series
Dataliner. Chapter 4 illustrates the connections.
Note: You must set the DL50 for Simplex protocol when communicating
with a DL40.
The position and size of the characters displayed on the DL50 is
determined by:
Number of lines available on the master DL40
Message attributes
When programming DL40 messages for a DL50, refer to the following charts
and suggestions.
Catalog No. 2706-F11J, -F11JC
2.1 Inch
Characters
2 Lines Available
4.8 Inch
Characters
1 Line Available
Auto Select
One or Two Lines
Available
DL40 Display Type
2 or 4 Line
2 Line
2 Line 4 Line
Catalog No. 2706-F21J, -F21JC
2.1 Inch
Characters
2 Lines Available
4.8 Inch
Characters
1 Line Available
Auto Select
One or Two Lines
Available
DL40 Display Type
2 or 4 Line
4 Line
2 Line 4 Line
Number of DL40 lines required to use all of the characters on each line of the DL50.
The DL50 will scroll the 20 characters from right to left, 10 (4.8 inch) characters at a time, unless the
DL40 slave message-length attribute is set to 10 characters.