User Manual

Rockwell Automation Publication 20P-UM001K-EN-P - July 2014 61
Installation and Wiring Chapter 1
Table 16 - DIP Switch S14 Field Current Configuration Settings Frames A, B and C Drives
Table 17 - DIP Switch S14 Field Current Configuration Settings for Frame D Drives and Standalone
Regulators with a Rated Field Supply of 40 A
Table 18 - DIP Switch S14 Field Current Configuration Settings for Frame D Drives and Standalone
Regulators with a Rated Field Supply of 70 A
Switch ohms > 168.5 333.3 182 36.4 845 1668 3333 Equivalent
Resistance
Field Current Scale S14-1 S14-2 S14-3 S14-4 S14-5 S14-6 S14-7 S14-8 Ohms
1 A OFF OFF OFF OFF OFF ON
Not used
(OFF)
1668
2 A OFF OFF OFF OFF ON OFF 845
3 A OFF OFF OFF OFF ON ON 560.9
5 A OFF ON OFF OFF OFF OFF 333.3
10 A ON OFF OFF OFF OFF OFF 168.5
13 A ON OFF OFF OFF ON ON 129.6
17 A OFF ON ON OFF ON ON 97.3
20 A ON OFF ON OFF OFF ON 83.1
Switch ohms > 168.5 333.3 182 36.4 845 1668 3333 Equivalent
Resistance
Field Current Scale S14-1 S14-2 S14-3 S14-4 S14-5 S14-6 S14-7 S14-8 Ohm
1 A OFF OFF OFF OFF OFF OFF ON
Not
used
(OFF)
3333
2 A OFF OFF OFF OFF OFF ON OFF 1668
4 A OFF OFF OFF OFF ON OFF OFF 845
6 A OFF OFF OFF OFF ON ON OFF 560.9
10 A OFF ON OFF OFF OFF OFF OFF 333.3
20 A ON OFF OFF OFF OFF OFF OFF 168.5
30 A ON ON OFF OFF OFF OFF OFF 111.9
40 A ON OFF ON OFF OFF ON OFF 83.1
Switch ohms > 168.5 333.3 182 36.4 845 1668 3333 Equivalent
Resistance
Field Current Scale S14-1 S14-2 S14-3 S14-4 S14-5 S14-6 S14-7 S14-8 Ohm
1 A OFF OFF OFF OFF OFF ON OFF
Not
used
(OFF)
1668
5 A OFF ON OFF OFF OFF OFF OFF 333.3
10 A ON OFF OFF OFF OFF OFF OFF 168.5
20 A ON OFF ON OFF OFF ON OFF 83.1
50 A OFF ON OFF ON OFF OFF OFF 32.8
70 A ONONONONOFFOFFOFF 23.9