User Manual
Rockwell Automation Publication 20P-UM001K-EN-P - July 2014 243
Supplemental Drive Information Appendix A
Table 58 - 575V AC Input Drives
Table 59 - 690V AC Input Drives
Figure 72 - Frame C Field Circuit Fuse Location
Frame
Drive
Current
Rating
Code
Field
Amps
Type Qty Bussmann Mersen SIBA
C 540
20 10 x 38 mm
2
FWC-25A10F
A60Q25-2
6003305.25
675 A60Q25-8
D 810
40 22 x 58 mm FWP-50A22F A70QS50-22F 5014006.50
1K0
1K2
1K3
1K6
Frame
Drive
Current
Rating
Code
Field
Amps
Type Qty Bussmann Mersen SIBA
C 452
20 10 x 38 mm
2
FWC-25A10F
A60Q25-2
6003305.25
565 A60Q25-8
D 678
40
22 x 58 mm
FWP-50A22F A70QS50-22F 5014006.50
791
904
1K0
1K1
70 FWP-100A22F A70QS100-22F 5014006.100
1K2
1K4
1K5
Field circuit fuses are on the control board EMI shield next to the control board.
Note: Drive shown with front covers removed.