Table 49 - 575V AC Input Drives
Frame A and B Armature DC Output Fuses
Armature DC output fuses are externally mounted for frame A and B drives and
must be sourced separately. These fuses are required on four quadrant drives only,
but highly recommended on two quadrant drives. See Fuse Code FS2 in
Figure 68
on page 236.
Table 50 - 230V AC Input Drives
Frame Drive Current
Rating Code
DC Amps AC Line
Amps
Bussmann Mersen
North American FWP Type North American A70QS Type
B 067 67.5 55.1 FWP-100A A70QS100-4
101 101.3 82.7 FWP-175A A70QS175-4K
135 135 110.3 FWP-225A A70QS225-4
270 270 220.6 FWP-450A A70QS450-4
405 405 330.9 FWP-600A A70QS600-4K
Frame
Drive
Current
Rating
Code
DC
Amps
AC Line
Amps
Bussmann Mersen
Ferrule FWP Type North American
FWP Type
Ferrule A70QS
Type
North American
A70P / A70QS
Type
A 7P0 7 5.7 FWP-15A14F FWP-15B A70QS16-14F A70P15-4
9P0 9 7.4 FWP-20A14F FWP-20B A70QS20-14F A70P20-4
012 12 9.8 FWP-25A14F FWP-25B A70QS25-14F A70P25-4
020 20 16 FWP-40A14F FWP-40B A70QS40-14F A70QS40-4
029 29 24 FWP-63A22F FWP-60B A70QS63-22F A70QS60-4
038 38 31 FWP-80A22F FWP-80B A70QS80-22F A70QS80-4
055 55 45 – FWP-125A – A70QS125-4K
073 73 60 – FWP-150A – A70QS150-4K
093 93 76 – FWP-200A – A70QS200-4K
110 110 90 – FWP-225A – A70QS250-4
B 146 146 119 – FWP-300A – A70QS300-4
180 180 147 – FWP-350A A70QS350-4
218 218 178 – FWP-450A – A70QS450-4
265 265 217 – FWP-600A – A70QS600-4K
360 360 294 – FWP-700A – A70QS700-4
434 434 355 – FWP-900A – A70P900-4